Sciencetech has a large selection of "stand alone" and "open architecture" off-the-shelf and custom made products for researchers using spectroscopy or working with photovoltaics. We offer technical staff to help with the development of custom systems for special applications. Since 1985, Sciencetech has manufactured Modular Instrumentation for Spectroscopy, TeraHertz FTIRs, Highly Collimated Large Solar Simulators, Flash and Continuous Solar Simulators, Photovoltaic Instrumentation, Quantum Efficiency and Spectral Response Systems, Spectrophotometers/radiometers, Monochromators, Detection Systems, and Light Sources to offer to the global research community through a network of representatives.

 here

Sciencetech product design

SCIENCETECH has built a reputation on custom solutions. Whether you need a small modification to an existing system or a completely novel design built from the ground up to meet your technical specifications, Sciencetech's engineering and optical design teams are ready to help.

SCIENCETECH prides itself on our ability to build custom solutions and systems to the most exacting of specifications. Whether you need higher sensitivity, better throughput, more power, better spectral matching, higher resolution, or any other variable modified to give you exactly what you need, our team of engineers, physicists, and optical designers stand ready to provide you with a solution that will meet your technical requirements.

SCIENCETECH'S SOLAR SIMULATORS IN ACTION - The European Commission just released an article involving the use of Sciencetech's solar simulators in their new facility. Read the full article HERE.

X

Product Category

View Filter

x
Clear all x

Filter Option



Sciencetech's [130-REC] is a cooling water recirculator. It is designed to work with any of Sciencetech's liquid cooled solar cell chucks. This recirculator can maintain your sample at room temperature while sinking up to 500W of power from your light source.

-Dissipates up to 500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate
1,733.00
In Stock
Sciencetech's [130-REC] is a cooling water recirculator. It is designed to work with any of Sciencetech's liquid cooled solar cell chucks. This recirculator can maintain your sample at room temperature while sinking up to 500W of power from your light source.

-Dissipates up to 500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate
1,733.00 1733.0 USD
Price Valid only in North America


Sciencetech's (160-REC) is a cooling water recirculator. It is designed to work with any of Sciencetech's liquid cooled solar cell chucks. This recirculator can maintain your sample at room temperature while sinking up to 900W of power from your light source.

-Dissipates up to 900W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate
2,036.00
In Stock
Sciencetech's (160-REC) is a cooling water recirculator. It is designed to work with any of Sciencetech's liquid cooled solar cell chucks. This recirculator can maintain your sample at room temperature while sinking up to 900W of power from your light source.

-Dissipates up to 900W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate
2,036.00 2036.0 USD
Price Valid only in North America


Sciencetech's Model [210-REC] is a Cooling Water Recirculator. It can sink up to 2500W of heat.

-Dissipates up to 2500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate

Sciencetech's Model [210-REC] is a Cooling Water Recirculator. It can sink up to 2500W of heat.

-Dissipates up to 2500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate

2,222.00 2222.0 USD
Price Valid only in North America


Spectralon Reflective Coating Standard,( Zenith White and Gold Coating available)
1.5" diameter entrance/exit port (1), 1" diameter application ports (3) (90 degree, North Pole and 180 degree)
Additional Ports and reduction of ports possible
Internal baffle on 90 deg port

3,718.00
In Stock
Spectralon Reflective Coating Standard,( Zenith White and Gold Coating available)
1.5" diameter entrance/exit port (1), 1" diameter application ports (3) (90 degree, North Pole and 180 degree)
Additional Ports and reduction of ports possible
Internal baffle on 90 deg port

3,718.00 3718.0 USD
Price Valid only in North America


This is an upgrade to Sciencetech's High Resolution monochromators, including the 9040, 9490, and 9150 (for both the Single and Double Pass configurations of these systems). It moves the input slit from the default position on the front of the monochromator to the side or lateral position.
Please note that this upgrade does not allow both input ports to be used, it only moves the position. If you require both input ports and the flipping mirror to select between them, please see DPIN-HI products.
This is an upgrade to Sciencetech's High Resolution monochromators, including the 9040, 9490, and 9150 (for both the Single and Double Pass configurations of these systems). It moves the input slit from the default position on the front of the monochromator to the side or lateral position.
Please note that this upgrade does not allow both input ports to be used, it only moves the position. If you require both input ports and the flipping mirror to select between them, please see DPIN-HI products.
453.00 453.0 USD
Price Valid only in North America


This upgrade is for Sciencetech's High Resolution line of monochromators, including the 9040, 9490, and 9150 (for both the single and double pass options for those systems). It moves the output port from the front of the monochromator to the side or lateral position. This allows different orientations of the system in relation to various sample chambers or detectors, and may be required depending on the size of the detector you are using due to the close proximity and limited space between the input and output slit on the front plate.
Please note that this upgrade does not allow both output ports to be used; it only moves the default output from the front of the system to the side. If you require both output ports be usable, please see DPOUT-HI products.
This upgrade is for Sciencetech's High Resolution line of monochromators, including the 9040, 9490, and 9150 (for both the single and double pass options for those systems). It moves the output port from the front of the monochromator to the side or lateral position. This allows different orientations of the system in relation to various sample chambers or detectors, and may be required depending on the size of the detector you are using due to the close proximity and limited space between the input and output slit on the front plate.
Please note that this upgrade does not allow both output ports to be used; it only moves the default output from the front of the system to the side. If you require both output ports be usable, please see DPOUT-HI products.
368.00 368.0 USD
Price Valid only in North America


This mount will attach cryogenic detectors directly to a Sciencetech monochromator or spectrometer. Please note that this mount is designed specifically for cryogenically cooled detectors, and may not function for other types of detectors. If you are uncertain about whether you need this mount or not, please contact your Sciencetech Representative.
530.00
In Stock
This mount will attach cryogenic detectors directly to a Sciencetech monochromator or spectrometer. Please note that this mount is designed specifically for cryogenically cooled detectors, and may not function for other types of detectors. If you are uncertain about whether you need this mount or not, please contact your Sciencetech Representative.
530.00 530.0 USD
Price Valid only in North America


This is a quick release mount for many of Sciencetech's standard single element detectors or PMTs. It allows the user to easily replace one detector with another, and remain confident in the ability of the system to hold and align various detectors properly with minimal effort. This will not work with either LDA or CCD systems or Cryogenic detectors. Please speak to your Technical Sales member at Sciencetech for more information.
202.00
In Stock
This is a quick release mount for many of Sciencetech's standard single element detectors or PMTs. It allows the user to easily replace one detector with another, and remain confident in the ability of the system to hold and align various detectors properly with minimal effort. This will not work with either LDA or CCD systems or Cryogenic detectors. Please speak to your Technical Sales member at Sciencetech for more information.
202.00 202.0 USD
Price Valid only in North America


A standard single-element detector mount for Sciencetech's line of monochromators and/or spectrometers. This quick release mount comes complete with Sciencetech's quick release mount (125-8012) as well as a quick release flange which mounts to a detector or component. The quick release flange has an internal 1.035-40 thread which can be used to mount Sciencetech's 525-5 line of detectors as well as other common optical components such as Thorlabs 1" lens tubes.

Please note that this mount will not work with dewer style detectors. If you are uncertain about what type of detector mount your system needs, please contact your Sciencetech representative.
183.00
In Stock
A standard single-element detector mount for Sciencetech's line of monochromators and/or spectrometers. This quick release mount comes complete with Sciencetech's quick release mount (125-8012) as well as a quick release flange which mounts to a detector or component. The quick release flange has an internal 1.035-40 thread which can be used to mount Sciencetech's 525-5 line of detectors as well as other common optical components such as Thorlabs 1" lens tubes.

Please note that this mount will not work with dewer style detectors. If you are uncertain about what type of detector mount your system needs, please contact your Sciencetech representative.
183.00 183.0 USD
Price Valid only in North America


The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS spectral region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model. Two gratings are required.

The 9030DA is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00
In Stock
The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS spectral region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model. Two gratings are required.

The 9030DA is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00 9493.0 USD
Price Valid only in North America


The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.

Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR spectral region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model. Two gratings are required.

The 9030DA is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00
In Stock
The 9030DA double additive monochromator consists of two 9030 monochromators placed in series. Stray light is drastically reduced in a double monochromator, and in the 9030DA it is further minimized by the use of concave holographic gratings. The inbound light is dispersed by the first grating and again by the second. Both gratings rotate simultaneously in the same direction, and the monochromators are coupled so that the dispersion is double that of a single 9030 monochromator. Bandpass is half of the corresponding 9030 monochromator for the same output slit, and resolution using a 100 µm slit is 0.4 nm.

Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR spectral region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model. Two gratings are required.

The 9030DA is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00 9493.0 USD
Price Valid only in North America


The 9030DS consists of two 100 mm scanning monochromators placed in series in subtractive mode. Bandpass is determined by the width of an intermediate slit, but the 9030DS has a net output dispersion of zero because the monochromators are optically coupled so that the dispersion of the second grating cancels that of the first. This leads to homogenized wavelengths at the output port - there is no spectrum, only a single undispersed slit image - which allows the unit to act as a tunable bandpass or notch filter.

Stray light of all sorts is drastically reduced in a double monochromator, and in the 9030DS it is further minimized by the use of concave holographic gratings. It is ideal for applications where stray light is a problem - where there may be a strong scattered background, such as in spectroradiometry, Raman, or measurements of solar radiation.

The 9030DS can be used as a tunable notch filter to remove one particular wavelength while allowing all others over the bandpass to pass through, making it an ideal instrument to pre-filter out the strong laser excitation wavelength in a fluorescence or Raman system so that the weaker output signals can be observed.

The 9030DS is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

The Model 9030DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit. Please contact a Sciencetech Applications Specialist for such custom wavelength filtering.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model. Two gratings are required.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00
In Stock
The 9030DS consists of two 100 mm scanning monochromators placed in series in subtractive mode. Bandpass is determined by the width of an intermediate slit, but the 9030DS has a net output dispersion of zero because the monochromators are optically coupled so that the dispersion of the second grating cancels that of the first. This leads to homogenized wavelengths at the output port - there is no spectrum, only a single undispersed slit image - which allows the unit to act as a tunable bandpass or notch filter.

Stray light of all sorts is drastically reduced in a double monochromator, and in the 9030DS it is further minimized by the use of concave holographic gratings. It is ideal for applications where stray light is a problem - where there may be a strong scattered background, such as in spectroradiometry, Raman, or measurements of solar radiation.

The 9030DS can be used as a tunable notch filter to remove one particular wavelength while allowing all others over the bandpass to pass through, making it an ideal instrument to pre-filter out the strong laser excitation wavelength in a fluorescence or Raman system so that the weaker output signals can be observed.

The 9030DS is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

The Model 9030DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit. Please contact a Sciencetech Applications Specialist for such custom wavelength filtering.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model. Two gratings are required.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00 9493.0 USD
Price Valid only in North America


The 9030DS consists of two 100 mm scanning monochromators placed in series in subtractive mode. Bandpass is determined by the width of an intermediate slit, but the 9030DS has a net output dispersion of zero because the monochromators are optically coupled so that the dispersion of the second grating cancels that of the first. This leads to homogenized wavelengths at the output port - there is no spectrum, only a single undispersed slit image - which allows the unit to act as a tunable bandpass or notch filter.

Stray light of all sorts is drastically reduced in a double monochromator, and in the 9030DS it is further minimized by the use of concave holographic gratings. It is ideal for applications where stray light is a problem - where there may be a strong scattered background, such as in spectroradiometry, Raman, or measurements of solar radiation.

The 9030DS can be used as a tunable notch filter to remove one particular wavelength while allowing all others over the bandpass to pass through, making it an ideal instrument to pre-filter out the strong laser excitation wavelength in a fluorescence or Raman system so that the weaker output signals can be observed.

The 9030DS is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

The Model 9030DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit. Please contact a Sciencetech Applications Specialist for such custom wavelength filtering.

Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model. Two gratings are required.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00
In Stock
The 9030DS consists of two 100 mm scanning monochromators placed in series in subtractive mode. Bandpass is determined by the width of an intermediate slit, but the 9030DS has a net output dispersion of zero because the monochromators are optically coupled so that the dispersion of the second grating cancels that of the first. This leads to homogenized wavelengths at the output port - there is no spectrum, only a single undispersed slit image - which allows the unit to act as a tunable bandpass or notch filter.

Stray light of all sorts is drastically reduced in a double monochromator, and in the 9030DS it is further minimized by the use of concave holographic gratings. It is ideal for applications where stray light is a problem - where there may be a strong scattered background, such as in spectroradiometry, Raman, or measurements of solar radiation.

The 9030DS can be used as a tunable notch filter to remove one particular wavelength while allowing all others over the bandpass to pass through, making it an ideal instrument to pre-filter out the strong laser excitation wavelength in a fluorescence or Raman system so that the weaker output signals can be observed.

The 9030DS is a fully integrated unit with the two diffraction gratings coupled mechanically for accurate positioning, adjusted manually using a thumb-wheel. It can be upgraded to be motorized and controlled by a computer with the 9030 Motorized Upgrade. Only one motor and drive unit is required for both monochromators, enabling control via Sciencetech Sci-Mono Active-X library or full featured Sci-Spec software.

The Model 9030DS can also be used to pass or filter out several selected wavelengths by using a custom intermediate multi-slit mask instead of a single width intermediate slit. Please contact a Sciencetech Applications Specialist for such custom wavelength filtering.

Mirror coatings have been chosen for this model to enhance performance in the VIS-NIR region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model. Two gratings are required.

Please add a minimum of three slits (for the input, output, and intermediate position) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
9,493.00 9493.0 USD
Price Valid only in North America


This upgrade allows a manual 9030 to be operated by computer control. SciMono is included. Only a single motorized upgrade is required for 9030DS, 9030DA, or a single 9030.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
2,423.00
In Stock
This upgrade allows a manual 9030 to be operated by computer control. SciMono is included. Only a single motorized upgrade is required for 9030DS, 9030DA, or a single 9030.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
2,423.00 2423.0 USD
Price Valid only in North America


The Sciencetech 9030 monochromator is a compact, single grating, scanning monochromator with 100 mm focal length (both output and input). It has a manual wavelength selector dial with an optional external motor drive for computerized control. The compact design is made possible by its Seya-Namioka optical layout, using a single holographic concave grating and f/3.2 aperture. The input and output ports are purposely placed optically in-line, making it a simple addition to a straight line beam in an optical system. Being a scanning monochromator, it does not have a flat output field and hence cannot be operated as a spectrograph with a multi-channel detector mounted at the output port. However, it can be used as an excitation wavelength tunable light source.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model.

Please add a minimum of two slits (for the input and output) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
3,675.00
The Sciencetech 9030 monochromator is a compact, single grating, scanning monochromator with 100 mm focal length (both output and input). It has a manual wavelength selector dial with an optional external motor drive for computerized control. The compact design is made possible by its Seya-Namioka optical layout, using a single holographic concave grating and f/3.2 aperture. The input and output ports are purposely placed optically in-line, making it a simple addition to a straight line beam in an optical system. Being a scanning monochromator, it does not have a flat output field and hence cannot be operated as a spectrograph with a multi-channel detector mounted at the output port. However, it can be used as an excitation wavelength tunable light source.

Mirror coatings have been chosen for this model to enhance performance in the UV-VIS region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a UV to VIS range to pair with the UV/VIS mirror coatings on this model.

Please add a minimum of two slits (for the input and output) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
3,675.00 3675.0 USD
Price Valid only in North America


The Sciencetech 9030 monochromator is a compact, single grating, scanning monochromator with 100 mm focal length (both output and input). It has a manual wavelength selector dial with an optional external motor drive for computerized control. The compact design is made possible by its Seya-Namioka optical layout, using a single holographic concave grating and f/3.2 aperture. The input and output ports are purposely placed optically in-line, making it a simple addition to a straight line beam in an optical system. Being a scanning monochromator, it does not have a flat output field and hence cannot be operated as a spectrograph with a multi-channel detector mounted at the output port. However, it can be used as an excitation wavelength tunable light source.

Mirror coatings have been chosen for this model to enhance performance in the VIS-IR region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model.

Please add a minimum of two slits (for the input and output) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
3,574.00
The Sciencetech 9030 monochromator is a compact, single grating, scanning monochromator with 100 mm focal length (both output and input). It has a manual wavelength selector dial with an optional external motor drive for computerized control. The compact design is made possible by its Seya-Namioka optical layout, using a single holographic concave grating and f/3.2 aperture. The input and output ports are purposely placed optically in-line, making it a simple addition to a straight line beam in an optical system. Being a scanning monochromator, it does not have a flat output field and hence cannot be operated as a spectrograph with a multi-channel detector mounted at the output port. However, it can be used as an excitation wavelength tunable light source.

Mirror coatings have been chosen for this model to enhance performance in the VIS-IR region. There are 5 grating choices (sold separately) covering from UV to near-IR; choose a VIS to NIR range to pair with the VIS/IR mirror coatings on this model.

Please add a minimum of two slits (for the input and output) separately. Several removable fixed-width slit sizes are available to choose from ranging from 50 μm to 3 mm width. Please note that a 50μm slit may introduce some artifacts when used with the 9030 - this model is recommended to be used with slits of 100μm or larger for best performance in most applications. Additional removable slits and custom width slits can also be purchased.
Available slits include:
Model Slit Width
SF005 - 50 μm
SF010 - 100μm
SF025 - 250μm
SF050 - 500μm
SF100 - 1mm
SF200 - 2mm
SF300 - 3mm
3,574.00 3574.0 USD
Price Valid only in North America


The 9040 is Sciencetech's 0.5 m focal length monochromator. This model of monochromator accommodates a grating on a removable kinematic mount, allowing the user to manually swap one grating for another without losing alignment. This version can accommodate 64 x 64 mm, 84 x 84 mm, and 102 x 102 mm gratings. Please note that this product includes one slit, but does not include any additional slits or a grating, these must be purchased separately. Please speak with a technical sales member for assistance in selecting the right components for your system. SciMono is included. For Sciencetech's full feature spectroscopy software, please see SciSpec (not included).

Please see the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
The 9040 is Sciencetech's 0.5 m focal length monochromator. This model of monochromator accommodates a grating on a removable kinematic mount, allowing the user to manually swap one grating for another without losing alignment. This version can accommodate 64 x 64 mm, 84 x 84 mm, and 102 x 102 mm gratings. Please note that this product includes one slit, but does not include any additional slits or a grating, these must be purchased separately. Please speak with a technical sales member for assistance in selecting the right components for your system. SciMono is included. For Sciencetech's full feature spectroscopy software, please see SciSpec (not included).

Please see the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
31,612.00 31612.0 USD
Price Valid only in North America


The 9040 is Sciencetech's 0.5 m focal length monochromator. This model of monochromator accommodates up to 3 gratings on a rotational turret to automatically scan over all gratings through software. This version can accommodate 64 x 64 mm, 84 x 84 mm, and 102 x 102 mm gratings. Please note that this product includes one slit, but does not include any additional slits or a grating, these must be purchased separately. Please speak with a technical sales member for assistance in selecting the right components for your system. SciMono is included. For Sciencetech's full feature spectroscopy software, please see SciSpec (not included).

Please see the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
The 9040 is Sciencetech's 0.5 m focal length monochromator. This model of monochromator accommodates up to 3 gratings on a rotational turret to automatically scan over all gratings through software. This version can accommodate 64 x 64 mm, 84 x 84 mm, and 102 x 102 mm gratings. Please note that this product includes one slit, but does not include any additional slits or a grating, these must be purchased separately. Please speak with a technical sales member for assistance in selecting the right components for your system. SciMono is included. For Sciencetech's full feature spectroscopy software, please see SciSpec (not included).

Please see the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
70,699.00 70699.0 USD
Price Valid only in North America


The 9040DX is a Double Additive or Subtractive design of the half meter 9040. Special care has been taken to design the system to minimize and eliminate stray light whenever possible.
A double subtractive monochromator operates to create a monochromatic light source by the 2nd monochromator cancelling the dispersion caused by the 1st monochromator. This allows a Double Subtractive system to operate as a tunable notch filter for Raman applications. The double additive is used for improved resolution. Please see the technical datasheet or contact a Sciencetech Technical Representative for additional information.

Please note that 2 gratings are required for this system, minimum, but are not included. This version can accommodate 64 x 64 mm, 84 x 84 mm, and 102 x 102 mm gratings. Please note that this product includes one slit, but does not include any additional slits or a grating, these must be purchased separately. SciMono is included. For Sciencetech's full feature spectroscopy software, please see SciSpec (not included).

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
The 9040DX is a Double Additive or Subtractive design of the half meter 9040. Special care has been taken to design the system to minimize and eliminate stray light whenever possible.
A double subtractive monochromator operates to create a monochromatic light source by the 2nd monochromator cancelling the dispersion caused by the 1st monochromator. This allows a Double Subtractive system to operate as a tunable notch filter for Raman applications. The double additive is used for improved resolution. Please see the technical datasheet or contact a Sciencetech Technical Representative for additional information.

Please note that 2 gratings are required for this system, minimum, but are not included. This version can accommodate 64 x 64 mm, 84 x 84 mm, and 102 x 102 mm gratings. Please note that this product includes one slit, but does not include any additional slits or a grating, these must be purchased separately. SciMono is included. For Sciencetech's full feature spectroscopy software, please see SciSpec (not included).

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
59,185.00 59185.0 USD
Price Valid only in North America


The Sciencetech 9055 is a 250mm asymmetric focal length modified Czerny-Turner monochromator. It has a flat field output for use as a spectrograph. This model has an f/3.5 aperture (for the "Fast" version with f/2.5, please see the 9055F). It has a computer-controlled interchangeable turret for automatic grating and wavelength selection.
Both the input and output ports are located on the front faceplate of the monochromator, and the system includes one SS80 slit at the input port. CE compliant.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased. Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself. This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
8,538.00
In Stock
The Sciencetech 9055 is a 250mm asymmetric focal length modified Czerny-Turner monochromator. It has a flat field output for use as a spectrograph. This model has an f/3.5 aperture (for the "Fast" version with f/2.5, please see the 9055F). It has a computer-controlled interchangeable turret for automatic grating and wavelength selection.
Both the input and output ports are located on the front faceplate of the monochromator, and the system includes one SS80 slit at the input port. CE compliant.

It Includes a Sci-Mono, a Windows based software module with a simple graphical user interface for controlling Sciencetech stepping monochromator wavelength selection. SciMono is provided free of charge with a Sciencetech motorized monochromator when SciSpec software has not been purchased. Sciencetech Software (Sci-Spec) is available at an additional cost. It is a standalone data acquisition and allows controlling the monochromator by itself. This system does not include gratings or a host computer. If you require any of these components, please speak with your technical sales staff member.

Refer to the technical datasheet for additional information.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
8,538.00 8538.0 USD
Price Valid only in North America
Copyright © Sciencetech