Products | Sciencetech Inc.
Sciencetech has a large selection of "stand alone" and "open architecture" off-the-shelf and custom made products for researchers using spectroscopy or working with photovoltaics. We offer technical staff to help with the development of custom systems for special applications. Since 1985, Sciencetech has manufactured Modular Instrumentation for Spectroscopy, TeraHertz FTIRs, Highly Collimated Large Solar Simulators, Flash and Continuous Solar Simulators, Photovoltaic Instrumentation, Quantum Efficiency and Spectral Response Systems, Spectrophotometers/radiometers, Monochromators, Detection Systems, and Light Sources to offer to the global research community through a network of representatives.

 here

Sciencetech product design

SCIENCETECH has built a reputation on custom solutions. Whether you need a small modification to an existing system or a completely novel design built from the ground up to meet your technical specifications, Sciencetech's engineering and optical design teams are ready to help.

SCIENCETECH prides itself on our ability to build custom solutions and systems to the most exacting of specifications. Whether you need higher sensitivity, better throughput, more power, better spectral matching, higher resolution, or any other variable modified to give you exactly what you need, our team of engineers, physicists, and optical designers stand ready to provide you with a solution that will meet your technical requirements.

SCIENCETECH'S SOLAR SIMULATORS IN ACTION - The European Commission just released an article involving the use of Sciencetech's solar simulators in their new facility. Read the full article HERE.

X

Product Category

View Filter

x
Clear all x

Filter Option



Material: Si
Wavelength Range: 350-1100
Detector Size: 0.8mm diameter
Gain (Fixed): 100kV/A
Bandwidth Range: DC - 50MHz
NEP: 6.5x10^(-11) W/Hz^(1/2)
800.00
In stock
Material: Si
Wavelength Range: 350-1100
Detector Size: 0.8mm diameter
Gain (Fixed): 100kV/A
Bandwidth Range: DC - 50MHz
NEP: 6.5x10^(-11) W/Hz^(1/2)
800.00 800.0 USD
Price Valid only in North America


Material: Si
Wavelength Range: 200-1100
Detector Size: 1.0mm diameter
Gain (Fixed): 10kV/A
Bandwidth Range: DC - 150MHz
NEP: 5.5x10^(-11) W/Hz^(1/2)
632.00
In stock
Material: Si
Wavelength Range: 200-1100
Detector Size: 1.0mm diameter
Gain (Fixed): 10kV/A
Bandwidth Range: DC - 150MHz
NEP: 5.5x10^(-11) W/Hz^(1/2)
632.00 632.0 USD
Price Valid only in North America


With the Sciencetech Solar LightLine you can direct the Class AAA solar light anywhere you want. Classic designs for solar simulators require you to bring your sample to the solar simulator. Now, you can bring the solar simulator to your sample! This makes the Sciencetech Solar LightLine series of fiberized solar simulators ideal for research that just can't accommodate traditional bulky solar simulators. The solar light can be easily integrated with a glove box without mounting the entire solar simulator in the glove box, saving space and adding flexibility. The standard 4-foot-long fiber makes the simulator ideal for doing spot checks of devices on manufacturing lines or in dedicated setups that can't accommodate a bulky solar simulator.

The Lightline includes space for fitting one internal accessory. Options are a motorized, 6-position filter wheel, with a variety of spectral or neutral density filters that can be supplied. Or a manual or motorized attenuation system that provides continuous control over intensity at the target from 10-100%. Internal accessories must be selected at the time of order and cannot be added at a later time.

Every Lightline includes an internal two-position filter tray that accommodates Sciencetech FT style filters. Model AX-100 and AX-200 come with a removeable FT-style filter that permits one sun operation. One filter location is reserved for the selected air mass filter. Air mass filters must be selected in the order for spectral match classification.

Classification is performed to ASTM E927-19. Classification to IEC 60904-9 and JIS C 08912 standards can be performed on request. Please contact your Sciencetech Technical Representative for details.

- Includes adjustable touchscreen 601-series power supply with current control from 80-100% of max current.
- Includes computer-controlled high intensity shutter.
- Length of light guide: 4 feet (other light guide lengths are possible) Light guides can be fitted with KF flanges for glovebox integration.
- Includes one 300W xenon short arc lamp.

This unit runs on 120/220VAC.
CE compliant.
9,200.00
With the Sciencetech Solar LightLine you can direct the Class AAA solar light anywhere you want. Classic designs for solar simulators require you to bring your sample to the solar simulator. Now, you can bring the solar simulator to your sample! This makes the Sciencetech Solar LightLine series of fiberized solar simulators ideal for research that just can't accommodate traditional bulky solar simulators. The solar light can be easily integrated with a glove box without mounting the entire solar simulator in the glove box, saving space and adding flexibility. The standard 4-foot-long fiber makes the simulator ideal for doing spot checks of devices on manufacturing lines or in dedicated setups that can't accommodate a bulky solar simulator.

The Lightline includes space for fitting one internal accessory. Options are a motorized, 6-position filter wheel, with a variety of spectral or neutral density filters that can be supplied. Or a manual or motorized attenuation system that provides continuous control over intensity at the target from 10-100%. Internal accessories must be selected at the time of order and cannot be added at a later time.

Every Lightline includes an internal two-position filter tray that accommodates Sciencetech FT style filters. Model AX-100 and AX-200 come with a removeable FT-style filter that permits one sun operation. One filter location is reserved for the selected air mass filter. Air mass filters must be selected in the order for spectral match classification.

Classification is performed to ASTM E927-19. Classification to IEC 60904-9 and JIS C 08912 standards can be performed on request. Please contact your Sciencetech Technical Representative for details.

- Includes adjustable touchscreen 601-series power supply with current control from 80-100% of max current.
- Includes computer-controlled high intensity shutter.
- Length of light guide: 4 feet (other light guide lengths are possible) Light guides can be fitted with KF flanges for glovebox integration.
- Includes one 300W xenon short arc lamp.

This unit runs on 120/220VAC.
CE compliant.
9,200.00 9200.0 USD
Price Valid only in North America


This option for SS0.5K, SS1.0K and SS1.6K solar simulators makes the solar simulator vertical standing. With this option the output from the solar simulator will be parallel to the floor it is standing on.
400.00
This option for SS0.5K, SS1.0K and SS1.6K solar simulators makes the solar simulator vertical standing. With this option the output from the solar simulator will be parallel to the floor it is standing on.
400.00 400.0 USD
Price Valid only in North America


This option for SS0.5K, SS1.0K and SS1.6K solar simulators makes the solar simulator vertical standing. The base is fitted with castors so that the simulator can be easily moved. This option is very useful if the simulator location may be changed from time to time. With this option the output from the solar simulator will be parallel to the floor it is standing on.
500.00
This option for SS0.5K, SS1.0K and SS1.6K solar simulators makes the solar simulator vertical standing. The base is fitted with castors so that the simulator can be easily moved. This option is very useful if the simulator location may be changed from time to time. With this option the output from the solar simulator will be parallel to the floor it is standing on.
500.00 500.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00
In stock
This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00 1727.0 USD
Price Valid only in North America


4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00
In stock
4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00 7911.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,375.00
In stock
This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,375.00 1375.0 USD
Price Valid only in North America


This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 10A
5,000.00
This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 10A
5,000.00 5000.0 USD
Price Valid only in North America


This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 20A

6,000.00
This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 20A

6,000.00 6000.0 USD
Price Valid only in North America


This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 40A
7,000.00
This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 40A
7,000.00 7000.0 USD
Price Valid only in North America


This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 60A
8,000.00
This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 60A
8,000.00 8000.0 USD
Price Valid only in North America


This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 80A

8,500.00
This device is designed to be coupled to one of Sciencetech's IV Test systems. The Load Booster is inserted between the Keithley and the device under test with the Keithley current range set to 0.1A and used in remote (4 wire) sensing mode. The Load Booster effectively expands the IV testing current range.
Load Boosters may only be used in pulsed mode operation. They cannot be used for continuous illumination and measurement.
Voltage Range: 200V
Current Range: 80A

8,500.00 8500.0 USD
Price Valid only in North America


This broadband IR area detector has a sensor size of 320 x 240 pixels and a spectral range of 2-14 μm. The pixel size is 48.5μm square. The sensor is an uncooled pyroelectric BST (Barium, Strontium, Titanate) array. Because of the nature of pyroelectric sensors, there is an internal Archimedes spiral chopper that recalibrates the image. However, this calibration system, called an Auto Image Calibration, is actually a benefit for the user. The detector self calibrates to a reference 60 times per second, which in turn causes the system to be extremely stable and to have very little fixed pattern noise.
21,121.00
This broadband IR area detector has a sensor size of 320 x 240 pixels and a spectral range of 2-14 μm. The pixel size is 48.5μm square. The sensor is an uncooled pyroelectric BST (Barium, Strontium, Titanate) array. Because of the nature of pyroelectric sensors, there is an internal Archimedes spiral chopper that recalibrates the image. However, this calibration system, called an Auto Image Calibration, is actually a benefit for the user. The detector self calibrates to a reference 60 times per second, which in turn causes the system to be extremely stable and to have very little fixed pattern noise.
21,121.00 21121.0 USD
Price Valid only in North America


1,000.00 1000.0 USD
Price Valid only in North America


Alphalas 3648 pixel linear CCD.
UV to IR spectral range 200 - 1100 nm, 16-bit ADC, large 32 MB of fast DDR2 onboard RAM, max. 269.5 fps, high-speed USB 2.0
Housing: 90 x 25 x 105 mm (W x H x D)
Comes with specific USB power/signal cable for interfacing to a computer.
Works with Sciencetech SciSpec Software integrating camera readout and monochromator position information. This camera is also compatible with LabView. A C++ programming library is available for this camera at extra cost.

This camera can also be triggered using TTL signals making it a perfect option for interfacing with Sciencetech's high speed shutters for decay measurements.
2,717.00
In stock
Alphalas 3648 pixel linear CCD.
UV to IR spectral range 200 - 1100 nm, 16-bit ADC, large 32 MB of fast DDR2 onboard RAM, max. 269.5 fps, high-speed USB 2.0
Housing: 90 x 25 x 105 mm (W x H x D)
Comes with specific USB power/signal cable for interfacing to a computer.
Works with Sciencetech SciSpec Software integrating camera readout and monochromator position information. This camera is also compatible with LabView. A C++ programming library is available for this camera at extra cost.

This camera can also be triggered using TTL signals making it a perfect option for interfacing with Sciencetech's high speed shutters for decay measurements.
2,717.00 2717.0 USD
Price Valid only in North America


Rotating blade chopper
2 opening blade for frequency range of 4-200Hz.
Higher frequency ranges available with other blades.
Includes enclosure and driver
1-D slip ring with H4 hole pattern on input face, 2-D slip ring with S4 hole pattern on output face for integration with Sciencetech modular instruments.
** Warning ** This chopper accepts a maximum 1" diameter collimated beam at the chopper port. For 1" diameter collimated beams the CH-MC-E-1D1D chopper is usually used.
The CH-MC-E-1D2D chopper is usually used in cases where a convergent beam enters the chopper housing from a 2" optical tube.


This chopper is compatible with SciSpec and SciPV software. For integration into Sciencetech instruments or larger integrated systems see SciencetechCOM and SciAX software.

Third party control software is included with this chopper but is not supported by Sciencetech.
2,472.00
In stock
Rotating blade chopper
2 opening blade for frequency range of 4-200Hz.
Higher frequency ranges available with other blades.
Includes enclosure and driver
1-D slip ring with H4 hole pattern on input face, 2-D slip ring with S4 hole pattern on output face for integration with Sciencetech modular instruments.
** Warning ** This chopper accepts a maximum 1" diameter collimated beam at the chopper port. For 1" diameter collimated beams the CH-MC-E-1D1D chopper is usually used.
The CH-MC-E-1D2D chopper is usually used in cases where a convergent beam enters the chopper housing from a 2" optical tube.


This chopper is compatible with SciSpec and SciPV software. For integration into Sciencetech instruments or larger integrated systems see SciencetechCOM and SciAX software.

Third party control software is included with this chopper but is not supported by Sciencetech.
2,472.00 2472.0 USD
Price Valid only in North America


The C230X Chopper is a Sciencetech manufactured chopper for high precision applications requiring a vacuum-grade polarizing chopper and better accuracy than is available through most commercially available chopper systems.
This product is the enclosure required to mount one of these choppers to any system. Please discuss the exact desired location of the chopper relative to the rest of your system with your authorized Sciencetech technical sales staff member to ensure that your system meets all technical specifications and requirements.
650.00
In stock
The C230X Chopper is a Sciencetech manufactured chopper for high precision applications requiring a vacuum-grade polarizing chopper and better accuracy than is available through most commercially available chopper systems.
This product is the enclosure required to mount one of these choppers to any system. Please discuss the exact desired location of the chopper relative to the rest of your system with your authorized Sciencetech technical sales staff member to ensure that your system meets all technical specifications and requirements.
650.00 650.0 USD
Price Valid only in North America


Many systems require choppers for modulating signals (either inputs or outputs, depending on the system and detector, and the specific needs for modulation for the system). A chopper is normally the most effective way to do this.
However, the chopper normally requires a housing to hold the chopper in the proper position in the system. This particular housing is designed to allow a chopper to be mounted to either the input or output port of a Sciencetech monochromator or spectrograph.
If you have any questions about how this mounting may affect your system, please speak with your authorized Sciencetech technical sales staff member.
600.00
In stock
Many systems require choppers for modulating signals (either inputs or outputs, depending on the system and detector, and the specific needs for modulation for the system). A chopper is normally the most effective way to do this.
However, the chopper normally requires a housing to hold the chopper in the proper position in the system. This particular housing is designed to allow a chopper to be mounted to either the input or output port of a Sciencetech monochromator or spectrograph.
If you have any questions about how this mounting may affect your system, please speak with your authorized Sciencetech technical sales staff member.
600.00 600.0 USD
Price Valid only in North America


Sciencetech's sample chambers can be connected to either the input or output port of a Sciencetech monochromator/spectrograph. The coupling tube that connects them together is 1" in diameter, and has one lens with a matching monochromator F number. When the sample chamber is connected to the input port of a monochromator/spectrograph, collimated light from the sample chamber is then focused into the slit of the monochromator matching its input F number using a single lens. When the sample chamber is connected to the output port of a monochromator, the output light of the monochromator is collected by a single lens with matching output F number and then collimated for entry into the sample chamber.
This product includes the F-matching lens, tubes, and mechanical connections required to couple the sample chamber to the monochromator. Please specify if this will be an input or output coupling when ordering. This product will only work for Sciencetech's line of sample chambers: for custom optical coupling, please speak with your authorized Sciencetech technical sales staff member.
909.00
In stock
Sciencetech's sample chambers can be connected to either the input or output port of a Sciencetech monochromator/spectrograph. The coupling tube that connects them together is 1" in diameter, and has one lens with a matching monochromator F number. When the sample chamber is connected to the input port of a monochromator/spectrograph, collimated light from the sample chamber is then focused into the slit of the monochromator matching its input F number using a single lens. When the sample chamber is connected to the output port of a monochromator, the output light of the monochromator is collected by a single lens with matching output F number and then collimated for entry into the sample chamber.
This product includes the F-matching lens, tubes, and mechanical connections required to couple the sample chamber to the monochromator. Please specify if this will be an input or output coupling when ordering. This product will only work for Sciencetech's line of sample chambers: for custom optical coupling, please speak with your authorized Sciencetech technical sales staff member.
909.00 909.0 USD
Price Valid only in North America
Copyright © Sciencetech