Other Accessories | Sciencetech Inc.

Other Accessories

X

Product Category

View Filter

x
Clear all x

Filter Option



4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00
In stock
4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00 7911.0 USD
Price Valid only in North America


Target size: 500x500mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 800x800x125
7,475.00
In stock
Target size: 500x500mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 800x800x125
7,475.00 7475.0 USD
Price Valid only in North America


Target size: 350x350mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 600x600x125

Includes SciMeasurementStage software
6,485.00
In stock
Target size: 350x350mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 600x600x125

Includes SciMeasurementStage software
6,485.00 6485.0 USD
Price Valid only in North America


Target size: 100x100mm
DAQ: 16 bit
Detector size : 20x20mm (apertured to 12.5x12.5mm)
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 200x200x125
4,325.00
In stock
Target size: 100x100mm
DAQ: 16 bit
Detector size : 20x20mm (apertured to 12.5x12.5mm)
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 200x200x125
4,325.00 4325.0 USD
Price Valid only in North America


TC-1000-120 is a compressor-refrigerant recirculating liquid chiller rated at 900W, or 3071 BTU/hr (@25°C liquid & ambient). Chiller control is based on one of four configurable temperature set-points, including the option to lock liquid to ambient for avoiding condensation or to an external K-type thermocouple sensor (not included).

Coolant flow rate, temperature, and reservoir level are monitored, and a USB port allows control and logging of most features using the System Monitor application. A 0-5V differential voltage output is also provided for industrial process monitoring.

Cooling capacity: 900W (3071BTU/hr) @ 25°C liquid/ambient
Temperature options: liquid set-point, external thermocouple set-point, liquid and ambient delta-T, external thermocouple and ambient delta-T; toggle °C/°F
Pump: 10 manual levels, up to 11LPM (2.9 GPM)
Select only values you want displayed on the front 2-line OLED display (fixed or rotating)
Show pump impeller speed in RPM
Show coolant flow rate in LPM/GPM
Show condenser fan speed in RPM
Adjust audio alarm and relay trigger (NO or NC) based on: temperature, flow rate, coolant level, pump RPM, and condenser fan RPM
Refrigerant: R-134a
Power input: 220VAC, 50-60Hz
Maximum power consumption @ ambient (approximate): 450W @ 25°C, 650W @ 35°C
Designed for an operational temperature range of 0-40°C (ambient and liquid)
Reservoir capacity: 3 liters

This item contains all the necessary tubing and connections to connect to any of Sciencetech -L (liquid cooled) cell chucks.

Keep unit upright at all times, and for at least 24 hours before applying power to ensure sufficient oil reaches the compressor.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
3,450.00
In stock
TC-1000-120 is a compressor-refrigerant recirculating liquid chiller rated at 900W, or 3071 BTU/hr (@25°C liquid & ambient). Chiller control is based on one of four configurable temperature set-points, including the option to lock liquid to ambient for avoiding condensation or to an external K-type thermocouple sensor (not included).

Coolant flow rate, temperature, and reservoir level are monitored, and a USB port allows control and logging of most features using the System Monitor application. A 0-5V differential voltage output is also provided for industrial process monitoring.

Cooling capacity: 900W (3071BTU/hr) @ 25°C liquid/ambient
Temperature options: liquid set-point, external thermocouple set-point, liquid and ambient delta-T, external thermocouple and ambient delta-T; toggle °C/°F
Pump: 10 manual levels, up to 11LPM (2.9 GPM)
Select only values you want displayed on the front 2-line OLED display (fixed or rotating)
Show pump impeller speed in RPM
Show coolant flow rate in LPM/GPM
Show condenser fan speed in RPM
Adjust audio alarm and relay trigger (NO or NC) based on: temperature, flow rate, coolant level, pump RPM, and condenser fan RPM
Refrigerant: R-134a
Power input: 220VAC, 50-60Hz
Maximum power consumption @ ambient (approximate): 450W @ 25°C, 650W @ 35°C
Designed for an operational temperature range of 0-40°C (ambient and liquid)
Reservoir capacity: 3 liters

This item contains all the necessary tubing and connections to connect to any of Sciencetech -L (liquid cooled) cell chucks.

Keep unit upright at all times, and for at least 24 hours before applying power to ensure sufficient oil reaches the compressor.

This system includes 1 IEC 60320 C13 compatible power cables. Region-specific version must be selected at the time of placing an order (see product 491-9001).
3,450.00 3450.0 USD
Price Valid only in North America


The SCI-SCC6-B cell chuck is an economical way of providing electrical connection to the back of your test cells. It is compatible with all of Sciencetech's probe systems except the SCP-MP-T and SCP-MP-G. It is not capable of vacuum hold down.
Working Area: 6" x 6"
Temperature Range: N/A
Power Input: N/A
Power Usage: N/A
Options: N/A
3,099.00
In stock
The SCI-SCC6-B cell chuck is an economical way of providing electrical connection to the back of your test cells. It is compatible with all of Sciencetech's probe systems except the SCP-MP-T and SCP-MP-G. It is not capable of vacuum hold down.
Working Area: 6" x 6"
Temperature Range: N/A
Power Input: N/A
Power Usage: N/A
Options: N/A
3,099.00 3099.0 USD
Price Valid only in North America


Sciencetech's Model [210-REC] is a Cooling Water Recirculator. It sink up to 2500W of heat.

-Dissipates up to 2500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate

Sciencetech's Model [210-REC] is a Cooling Water Recirculator. It sink up to 2500W of heat.

-Dissipates up to 2500W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate

2,200.00 2200.0 USD
Price Valid only in North America


Sciencetech's [160-REC] is a cooling water recirculator. It is designed to work with any of Sciencetech's liquid cooled solar cell chucks. This recirculator can maintain your sample at room temperature while sinking up to 900W of power from your light source.

-Dissipates up to 900W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate
2,016.00
In stock
Sciencetech's [160-REC] is a cooling water recirculator. It is designed to work with any of Sciencetech's liquid cooled solar cell chucks. This recirculator can maintain your sample at room temperature while sinking up to 900W of power from your light source.

-Dissipates up to 900W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling rate
2,016.00 2016.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (such as the UNO-1, sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00
In stock
This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (such as the UNO-1, sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00 1727.0 USD
Price Valid only in North America
Copyright © Sciencetech