Accessories and Parts | Sciencetech Inc.

Accessories / Parts

X

Product Category

View Filter

x
Clear all x

Filter Option



This hot mirror filters out IR light to remove thermal heat on the target. However, standard hot mirrors also remove UV light as a side-effect which mean it cannot be used in UV applications. This special hot mirror removes IR light between 730-1100nm while preserving UVA and UVB light (280-400nm) in addition to visible light. This filter is ideal for Sciencetech UV solar simulators where the filtering of thermal heat on the target is desired and preservation of UVA and UVB light is required.FT
This filter is intended for use at 0 degree angle of incidence.

This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

Please note this filter does not eliminate all thermal heat in the IR range as this filter stops at 1,100nm. Hence IR heat beyond 1,100nm still pass through. To remove more IR light see Sciencetech's range of IR water filters or contact a Sciencetech application scientist to learn about other options.
600.00
In stock
This hot mirror filters out IR light to remove thermal heat on the target. However, standard hot mirrors also remove UV light as a side-effect which mean it cannot be used in UV applications. This special hot mirror removes IR light between 730-1100nm while preserving UVA and UVB light (280-400nm) in addition to visible light. This filter is ideal for Sciencetech UV solar simulators where the filtering of thermal heat on the target is desired and preservation of UVA and UVB light is required.FT
This filter is intended for use at 0 degree angle of incidence.

This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

Please note this filter does not eliminate all thermal heat in the IR range as this filter stops at 1,100nm. Hence IR heat beyond 1,100nm still pass through. To remove more IR light see Sciencetech's range of IR water filters or contact a Sciencetech application scientist to learn about other options.
600.00 600.0 USD
Price Valid only in North America


This filter is mounted in a FT style filter holder and has a clear aperture of 76.2mm diameter
This filter is suitable for use with Sciencetechs line of SS solar simulators.
This filter blocks UVA light and transmits UVB as well as visible and IR light. This filter has an average transmission of better than 70% from 260-315nm, and reflection great than 95% from 320 to 400nm.
800.00
In stock
This filter is mounted in a FT style filter holder and has a clear aperture of 76.2mm diameter
This filter is suitable for use with Sciencetechs line of SS solar simulators.
This filter blocks UVA light and transmits UVB as well as visible and IR light. This filter has an average transmission of better than 70% from 260-315nm, and reflection great than 95% from 320 to 400nm.
800.00 800.0 USD
Price Valid only in North America


This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

Visible band block, UV pass filter
Clear aperture 3" diameter
Pass band 280-390nm
Blocking 420-750nm
Interference filter
Angle of incidence = 0 deg

2,000.00
In stock
This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

Visible band block, UV pass filter
Clear aperture 3" diameter
Pass band 280-390nm
Blocking 420-750nm
Interference filter
Angle of incidence = 0 deg

2,000.00 2000.0 USD
Price Valid only in North America


This filter is mounted in a FT style filter holder and has a clear aperture of 76.2mm diameter
This filter blocks UV and NIR light and transmits visible light. This filter has an average transmission of 95% from 400-700nm, and high reflection <400nm and from 700-1200nm.
400.00
In stock
This filter is mounted in a FT style filter holder and has a clear aperture of 76.2mm diameter
This filter blocks UV and NIR light and transmits visible light. This filter has an average transmission of 95% from 400-700nm, and high reflection <400nm and from 700-1200nm.
400.00 400.0 USD
Price Valid only in North America


This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

NIR Long pass filter
Clear aperture 3" diameter
Pass band 700-2000 nm
Blocking <700 nm
Interference filter
Angle of incidence = 0 deg
600.00
In stock
This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

NIR Long pass filter
Clear aperture 3" diameter
Pass band 700-2000 nm
Blocking <700 nm
Interference filter
Angle of incidence = 0 deg
600.00 600.0 USD
Price Valid only in North America


This long pass filter is made of absorbing glass. It is primarily used to remove UV light. It is effective at removing wavelengths <320nm.

This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.
400.00
In stock
This long pass filter is made of absorbing glass. It is primarily used to remove UV light. It is effective at removing wavelengths <320nm.

This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.
400.00 400.0 USD
Price Valid only in North America


This long pass filter is made of absorbing glass. It is primarily used to remove UV light. It is effective at removing wavelengths <400nm.

This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

600.00
In stock
This long pass filter is made of absorbing glass. It is primarily used to remove UV light. It is effective at removing wavelengths <400nm.

This filter is mounted in Sciencetech FT style filter mount with a 76.2mm diameter clear aperture.

600.00 600.0 USD
Price Valid only in North America


IR broad band pass filter, operating in approximately 2.5um to 5.0um.
This price includes the filter only; it does not include a holder, which must be purchased separately.

1,150.00
In stock
IR broad band pass filter, operating in approximately 2.5um to 5.0um.
This price includes the filter only; it does not include a holder, which must be purchased separately.

1,150.00 1150.0 USD
Price Valid only in North America


This coupling tube connects the Model 200-1K arc lamp housing to the Model FH-AC air-cooled dual filter holder box. Its length is designed specifically to place the air-cooled filter holder with 2" diameter filters in the converging beam of the light source. A mating flange connects this input extension coupling tube with the Model 200-1K arc lamp housing.
576.00
In stock
This coupling tube connects the Model 200-1K arc lamp housing to the Model FH-AC air-cooled dual filter holder box. Its length is designed specifically to place the air-cooled filter holder with 2" diameter filters in the converging beam of the light source. A mating flange connects this input extension coupling tube with the Model 200-1K arc lamp housing.
576.00 576.0 USD
Price Valid only in North America


The IRE-12 a coiled filament operating at approximately 900 degrees Celsius when powered with 10 watts. The radiating element is a coil of resistance wire which has a high emissivity in the Infrared spectral region. The coil is supported by a grooved cylindrical substrate of alumina, resulting in the windings being electrically insulated from each other. This contributes to a more uniform radiating source. The unit does not require operation in a sealed atmosphere. The header is fabricated from cold-rolled steel. The support pins are hermetically sealed in glass.
263.00
In stock
The IRE-12 a coiled filament operating at approximately 900 degrees Celsius when powered with 10 watts. The radiating element is a coil of resistance wire which has a high emissivity in the Infrared spectral region. The coil is supported by a grooved cylindrical substrate of alumina, resulting in the windings being electrically insulated from each other. This contributes to a more uniform radiating source. The unit does not require operation in a sealed atmosphere. The header is fabricated from cold-rolled steel. The support pins are hermetically sealed in glass.
263.00 263.0 USD
Price Valid only in North America


This 150W Xe bulb is recommended for Sciencetch solar simulator model SS150 only. It is a specially designed lamp to improve the uniformity of the SS150.
957.00
In stock
This 150W Xe bulb is recommended for Sciencetch solar simulator model SS150 only. It is a specially designed lamp to improve the uniformity of the SS150.
957.00 957.0 USD
Price Valid only in North America


A 300W "super quiet" arc lamp replacement bulb.
1,103.00
In stock
A 300W "super quiet" arc lamp replacement bulb.
1,103.00 1103.0 USD
Price Valid only in North America


This one of the standard Xenon lamp recommended for the Model 500-500 Power Supply. Although it is rated at 450W, it can be driven at 500W with little effect on its service life. (18V 25A, 1300cd, avg life 2000 hours, length 260mm)
868.00
In stock
This one of the standard Xenon lamp recommended for the Model 500-500 Power Supply. Although it is rated at 450W, it can be driven at 500W with little effect on its service life. (18V 25A, 1300cd, avg life 2000 hours, length 260mm)
868.00 868.0 USD
Price Valid only in North America


A Linear array sensitive in the 200 to 1000nm range.
System includes:
Photodiode array LDA 2000-1024 detector
Power supply
All cables and connections required for the system
A/D data acquisition board
Includes free version of SciRunLDA, a basic library for interfacing with other software. We recommend SciLDA, the full software package, for users who want a full feature system.
5,571.00
In stock
A Linear array sensitive in the 200 to 1000nm range.
System includes:
Photodiode array LDA 2000-1024 detector
Power supply
All cables and connections required for the system
A/D data acquisition board
Includes free version of SciRunLDA, a basic library for interfacing with other software. We recommend SciLDA, the full software package, for users who want a full feature system.
5,571.00 5571.0 USD
Price Valid only in North America


A Linear array sensitive in the 200 to 1000nm range.
System includes:
Photodiode array LDA 2000-512 detector
Power supply
All cables and connections required for the system
A/D data acquisition board and basic software library
5,459.00
In stock
A Linear array sensitive in the 200 to 1000nm range.
System includes:
Photodiode array LDA 2000-512 detector
Power supply
All cables and connections required for the system
A/D data acquisition board and basic software library
5,459.00 5459.0 USD
Price Valid only in North America


The LIA / PS-1 is a combination lock-in amplifier and low noise power supply which powers Sciencetech's detectors to the receiver preamplifiers. In addition, the PS-1 works well as a general purpose, dual - polarity laboratory power supply.
1,500.00
In stock
The LIA / PS-1 is a combination lock-in amplifier and low noise power supply which powers Sciencetech's detectors to the receiver preamplifiers. In addition, the PS-1 works well as a general purpose, dual - polarity laboratory power supply.
1,500.00 1500.0 USD
Price Valid only in North America


Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled 1.6K
5u - 2000u spectral range
Liquid Nitrogen required in outer jacket (dual stage cooling)
2.5 mm diameter diamond absorber
0.5" F/3.8 diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included

Filterwheel Position #1 - Long pass 5micron cut-on
Position #2 - Wedged P13 filter (13micron cut-on long pass)
Position #3 - Wedged C103 filter (103 micron cut-on long pass filter)
Wedged Diamond window Diameter = 25.0mm


54,340.00
In stock
Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled 1.6K
5u - 2000u spectral range
Liquid Nitrogen required in outer jacket (dual stage cooling)
2.5 mm diameter diamond absorber
0.5" F/3.8 diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included

Filterwheel Position #1 - Long pass 5micron cut-on
Position #2 - Wedged P13 filter (13micron cut-on long pass)
Position #3 - Wedged C103 filter (103 micron cut-on long pass filter)
Wedged Diamond window Diameter = 25.0mm


54,340.00 54340.0 USD
Price Valid only in North America


Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders of magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled to 4.2K
Liquid Nitrogen required in outer jacket (dual stage cooling)
Response for 20~100um, with some sensitivity up to 300um
0.5" diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included

See below for more specifications.
Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders of magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled to 4.2K
Liquid Nitrogen required in outer jacket (dual stage cooling)
Response for 20~100um, with some sensitivity up to 300um
0.5" diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included

See below for more specifications.
34,340.00 34340.0 USD
Price Valid only in North America


This Sample Chamber will operate at either 77K or at room temperature, but does not include any mechanism to regulate the temperature between those points.
It requires a supply of liquid nitrogen in order to operate (sold separately).

This Sample Chamber will operate at either 77K or at room temperature, but does not include any mechanism to regulate the temperature between those points.
It requires a supply of liquid nitrogen in order to operate (sold separately).

42,557.00 42557.0 USD
Price Valid only in North America


A custom built sample chamber capable of both vacuum operation and a choice of temperature ranges between 77K and room temperature.
The system requires liquid nitrogen, but does not include it.

While the system will be constructed for this temperature range, the mechanisms, pumps, and other equipment is sold separately.
This Sample Chamber requires EITHER 188-8901 OR 188-8903 to complete the sample chamber. Please ask your authorized Sciencetech technical sales staff member for further information.
A custom built sample chamber capable of both vacuum operation and a choice of temperature ranges between 77K and room temperature.
The system requires liquid nitrogen, but does not include it.

While the system will be constructed for this temperature range, the mechanisms, pumps, and other equipment is sold separately.
This Sample Chamber requires EITHER 188-8901 OR 188-8903 to complete the sample chamber. Please ask your authorized Sciencetech technical sales staff member for further information.
36,675.00 36675.0 USD
Price Valid only in North America
Copyright © Sciencetech