Single Channel Detectors | Sciencetech Inc.

Single Channel Detector

Sciencetech Single Channel Detectors

Detector Material and Spectral Region

Single channel detectors typically offer the smallest noise equivalent power (NEP values) and highest sensitivity levels. Single channel detectors are the best choice when you need to accurately measure extremely low light levels. Line and area detectors are typically used when measuring fast phenomena across multiple wavelengths (in a spectroscopic system).

Temperature Control

Some detectors can be temperature controlled or require cryogenics such as liquid helium or liquid nitrogen in order to be operable.

AC or DC Coupling

Some detectors are photoconductors and require modulated light in order to detect a signal. These types of detectors are listed as AC coupled. Generally, for AC coupled detectors a lock-in amplifier (LIA) or demodulator are required before measurements can be performed.

Detector Model Comparison


Contact Us Today
Get more information or request a quote.
X

Product Category

View Filter

x
Clear all x

Filter Option



This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately). Sciencetech's wideband detector design comes packaged in a mounting flange compatible with our SPS-300. It is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers with a detachable cable. The spectral range is limited by window selection. This detector comes with a HDPE window standard.

Element size: 2.0 mm dia.
Spectral bandwidth: 16 to 100um (for HDPE window, other window materials available)
Sensitivity: 200 V/W
Frequency response: 10Hz - 265Hz (-3db points)
N.E.P.: 5x10-10 watts (@100Hz)
Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections:
DB-9M
Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Signal Connection: BNC

Suitable for direct connection to Stanford SR-810/830 lockin preamp power (not included).

This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).
7,200.00
This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately). Sciencetech's wideband detector design comes packaged in a mounting flange compatible with our SPS-300. It is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers with a detachable cable. The spectral range is limited by window selection. This detector comes with a HDPE window standard.

Element size: 2.0 mm dia.
Spectral bandwidth: 16 to 100um (for HDPE window, other window materials available)
Sensitivity: 200 V/W
Frequency response: 10Hz - 265Hz (-3db points)
N.E.P.: 5x10-10 watts (@100Hz)
Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections:
DB-9M
Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Signal Connection: BNC

Suitable for direct connection to Stanford SR-810/830 lockin preamp power (not included).

This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).
7,200.00 7200.0 USD
Price Valid only in North America


Photon counting head using 28mm dia. Side on PMT. Spectral response range 185nm - 850nm. Low dark counts in UV to near IR range.
For full technical specifications, please contact your authorized Sciencetech technical sales staff member.
3,663.00
Photon counting head using 28mm dia. Side on PMT. Spectral response range 185nm - 850nm. Low dark counts in UV to near IR range.
For full technical specifications, please contact your authorized Sciencetech technical sales staff member.
3,663.00 3663.0 USD
Price Valid only in North America


A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 930nm.

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
2,170.00
In stock
A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 930nm.

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
2,170.00 2170.0 USD
Price Valid only in North America


A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 710nm.

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
730.00
In stock
A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 710nm.

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
730.00 730.0 USD
Price Valid only in North America


A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 900nm.
Special feature: extra low dark current, transit time 22ns
input window: 6x8 mm

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
1,020.00
In stock
A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 900nm.
Special feature: extra low dark current, transit time 22ns
input window: 6x8 mm

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
1,020.00 1020.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (such as the UNO-1, sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00
In stock
This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (such as the UNO-1, sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00 1727.0 USD
Price Valid only in North America


28 mm (1-1/8 inch) transmission mode S-1 photocathode, Side-on type.
Spectral Response: 400 - 1200nm
Wavelength of Maximum Response: 800nm
Minimum Effective Area (HxW): 16 x 18

Quantum Efficiency (at 25 degrees): 0.04% (Typical)
Anode Dark Current (after 30 min storage in darkness): 350 (typical), 1000 (max) nA
1,946.00
In stock
28 mm (1-1/8 inch) transmission mode S-1 photocathode, Side-on type.
Spectral Response: 400 - 1200nm
Wavelength of Maximum Response: 800nm
Minimum Effective Area (HxW): 16 x 18

Quantum Efficiency (at 25 degrees): 0.04% (Typical)
Anode Dark Current (after 30 min storage in darkness): 350 (typical), 1000 (max) nA
1,946.00 1946.0 USD
Price Valid only in North America


Multialkali high sensitivity side-on PMT
Spectral range: 185-900 nm,
Peak sensitivity wavelength: 400nm
Glass UV Envelope

Photocathode Area Size 8 x 24 mm
Photocathode Material Multialkali
Window Material UV glass
Dynode Structure Circular-cage
Anode to Cathode Voltage 1250 V
Average Anode Current 0.1 mA
Anode to Cathode Supply Voltage 1000 V
Luminous Sensitivity Min. 140 μA/lm
Luminous Sensitivity Typ. 250 μA/lm
Radiant Sensitivity Typ. 74 mA/W
Anode Luminous Sensitivity Min. 400 A/lm
Anode Luminous Sensitivity Typ. 2500 A/lm
Anode Radiant Sensitivity Typ. 7.4e5 A/W
Anode Dark Current (after 30min.) Typ. 3 nA
Anode Dark Current (after 30min.) Max. 50 nA
Time Response Rise Time Typ. 2.2 ns
Time Response Transit Time Typ. 22 ns
1,130.00
Multialkali high sensitivity side-on PMT
Spectral range: 185-900 nm,
Peak sensitivity wavelength: 400nm
Glass UV Envelope

Photocathode Area Size 8 x 24 mm
Photocathode Material Multialkali
Window Material UV glass
Dynode Structure Circular-cage
Anode to Cathode Voltage 1250 V
Average Anode Current 0.1 mA
Anode to Cathode Supply Voltage 1000 V
Luminous Sensitivity Min. 140 μA/lm
Luminous Sensitivity Typ. 250 μA/lm
Radiant Sensitivity Typ. 74 mA/W
Anode Luminous Sensitivity Min. 400 A/lm
Anode Luminous Sensitivity Typ. 2500 A/lm
Anode Radiant Sensitivity Typ. 7.4e5 A/W
Anode Dark Current (after 30min.) Typ. 3 nA
Anode Dark Current (after 30min.) Max. 50 nA
Time Response Rise Time Typ. 2.2 ns
Time Response Transit Time Typ. 22 ns
1,130.00 1130.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately - see below) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,030.00
In stock
This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately - see below) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,030.00 1030.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,375.00
In stock
This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,375.00 1375.0 USD
Price Valid only in North America


Integral HV power supply and display unit
4 digits LCD display
Analog BNC output
Available AD data acquisition system for capture to computer
Cooling temperature: -20°C. Warm-up time 10 minutes
Note: Cooling temperature is dependent on ambient temperature
Includes a small water recirculator (required for operation)
6,697.00
Integral HV power supply and display unit
4 digits LCD display
Analog BNC output
Available AD data acquisition system for capture to computer
Cooling temperature: -20°C. Warm-up time 10 minutes
Note: Cooling temperature is dependent on ambient temperature
Includes a small water recirculator (required for operation)
6,697.00 6697.0 USD
Price Valid only in North America


4 digits LCD displays high voltage output signal
BNC analog signal ouput
External high voltage control for the PMT (for computer control)
Six time constants switchable from a front panel control (from .01ms to 1sec.)
Zero adjustment control to cancel the effect of dark current and stray light
Adjustable gain 1, 10, 100 and 1,000 X
Includes power supply.
2,398.00
In stock
4 digits LCD displays high voltage output signal
BNC analog signal ouput
External high voltage control for the PMT (for computer control)
Six time constants switchable from a front panel control (from .01ms to 1sec.)
Zero adjustment control to cancel the effect of dark current and stray light
Adjustable gain 1, 10, 100 and 1,000 X
Includes power supply.
2,398.00 2398.0 USD
Price Valid only in North America
Copyright © Sciencetech