Single Channel Detector

Sciencetech Single Channel Detectors

Detector Material and Spectral Region

Single channel detectors typically offer the smallest noise equivalent power (NEP values) and highest sensitivity levels. Single channel detectors are the best choice when you need to accurately measure extremely low light levels. Line and area detectors are typically used when measuring fast phenomena across multiple wavelengths (in a spectroscopic system).

Temperature Control

Some detectors can be temperature controlled or require cryogenics such as liquid helium or liquid nitrogen in order to be operable.

AC or DC Coupling

Some detectors are photoconductors and require modulated light in order to detect a signal. These types of detectors are listed as AC coupled. Generally, for AC coupled detectors a lock-in amplifier (LIA) or demodulator are required before measurements can be performed.

Detector Model Comparison


Contact Us Today
Get more information or request a quote.
X

Product Category

View Filter

x
Clear all x

Filter Option



Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled 1.6K
5u - 2000u spectral range
Liquid Nitrogen required in outer jacket (dual stage cooling)
2.5 mm diameter diamond absorber
0.5" F/3.8 diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included

Filterwheel Position #1 - Long pass 5micron cut-on
Position #2 - Wedged P13 filter (13micron cut-on long pass)
Position #3 - Wedged C103 filter (103 micron cut-on long pass filter)
Wedged Diamond window Diameter = 25.0mm


54,340.00
In stock
Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled 1.6K
5u - 2000u spectral range
Liquid Nitrogen required in outer jacket (dual stage cooling)
2.5 mm diameter diamond absorber
0.5" F/3.8 diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included

Filterwheel Position #1 - Long pass 5micron cut-on
Position #2 - Wedged P13 filter (13micron cut-on long pass)
Position #3 - Wedged C103 filter (103 micron cut-on long pass filter)
Wedged Diamond window Diameter = 25.0mm


54,340.00 54340.0 USD
Price Valid only in North America


The Hot e- HEB detector system includes:
• HDL5 Helium dewar with Liquid Nitrogen cooled heat shield
• Liquid Helium Capacity -1.2 liters
• Liquid Nitrogen Capacity - 0.8 liters
• LHe hold time >20 hours
• Field of view baffle installed on heat shield
• Vacuum valve with burst disc and KF25 vacuum fitting
• Liquid Nitrogen fill and removal attachments
• Liquid Helium pumping/safety attachment
• Enhanced InSb Hot-e detector (HEB)
• Electrical Responsivity >5kV/W
• Detector Optical responsivity >3.5kV/W
• Detector electrical NEP < 500 fW.Hz-1/2
• Useful Frequency range 200- 5000 microns
• Frequency response ~ 500 kHz (-3dB)
• Operating resistance 5kOhms to 20 kOhms
• Operating Temperature 4.2K
• DC coupled response
• Physical size of element 5 mm x 4.7 mm x 300 um
• Detector installed in gold-plated copper substrate
• Cone optic assembly
• Entrance = 0.5”
• Exit = 0.196”
• Length = 0.813”
• 1" diameter wedged, Teflon window with diamond powder coating
• C285 wedged filter, 0.75” diameter, installed in front of cone entrance
• ULN6 preamplifier
50,000.00
In stock
The Hot e- HEB detector system includes:
• HDL5 Helium dewar with Liquid Nitrogen cooled heat shield
• Liquid Helium Capacity -1.2 liters
• Liquid Nitrogen Capacity - 0.8 liters
• LHe hold time >20 hours
• Field of view baffle installed on heat shield
• Vacuum valve with burst disc and KF25 vacuum fitting
• Liquid Nitrogen fill and removal attachments
• Liquid Helium pumping/safety attachment
• Enhanced InSb Hot-e detector (HEB)
• Electrical Responsivity >5kV/W
• Detector Optical responsivity >3.5kV/W
• Detector electrical NEP < 500 fW.Hz-1/2
• Useful Frequency range 200- 5000 microns
• Frequency response ~ 500 kHz (-3dB)
• Operating resistance 5kOhms to 20 kOhms
• Operating Temperature 4.2K
• DC coupled response
• Physical size of element 5 mm x 4.7 mm x 300 um
• Detector installed in gold-plated copper substrate
• Cone optic assembly
• Entrance = 0.5”
• Exit = 0.196”
• Length = 0.813”
• 1" diameter wedged, Teflon window with diamond powder coating
• C285 wedged filter, 0.75” diameter, installed in front of cone entrance
• ULN6 preamplifier
50,000.00 50000.0 USD
Price Valid only in North America


The NIR-PMT is contained in a thermally insulated, sealed-off housing evacuated to a high vacuum. Simple operation by air cooled TE cooler. It is a high sensitivity detector with a large detection area of 18mm for collimated light. It includes a HV power supply with interlock function.
Fast response time
Rise Time: 900 ps
TTS: 300 ps
This unit includes the housing, power supply, and detector components, but does not include mounting to a monochromator or sample chamber. Please include mounting separately.
44,625.00
In stock
The NIR-PMT is contained in a thermally insulated, sealed-off housing evacuated to a high vacuum. Simple operation by air cooled TE cooler. It is a high sensitivity detector with a large detection area of 18mm for collimated light. It includes a HV power supply with interlock function.
Fast response time
Rise Time: 900 ps
TTS: 300 ps
This unit includes the housing, power supply, and detector components, but does not include mounting to a monochromator or sample chamber. Please include mounting separately.
44,625.00 44625.0 USD
Price Valid only in North America


Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders of magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled to 4.2K
Liquid Nitrogen required in outer jacket (dual stage cooling)
Response for 20~100um, with some sensitivity up to 300um
0.5" diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included

See below for more specifications.
Liquid Helium Cooled Bolometers are 10^2 to 10^4 (two to four orders of magnitude) more sensitive than room temperature pyro-electric detectors
Liquid Helium Cooled to 4.2K
Liquid Nitrogen required in outer jacket (dual stage cooling)
Response for 20~100um, with some sensitivity up to 300um
0.5" diameter condensing cone as input optics
Preamp circuitry generates +/-14V max
5" Diameter Dewar Included

See below for more specifications.
34,340.00 34340.0 USD
Price Valid only in North America


4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00
In stock
4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00 7911.0 USD
Price Valid only in North America


This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).

Element size: 2.0mm diameter
Spectral bandwidth: Limited by selection of window
Sensitivity: 133,000 V/W (HDPE window)
Frequency Response: 8.8 - 265HZ (-3db points)
NEP: 1x10^-10 W (100Hz, 1Hz BW)
This is a room-temperature detector for use with the SPS-300. This includes the DTGS detector with a mounting flange, but requires the use of a dual-phase lock-in amplifier (sold separately).

Element size: 2.0mm diameter
Spectral bandwidth: Limited by selection of window
Sensitivity: 133,000 V/W (HDPE window)
Frequency Response: 8.8 - 265HZ (-3db points)
NEP: 1x10^-10 W (100Hz, 1Hz BW)
7,200.00 7200.0 USD
Price Valid only in North America


Integral HV power supply and display unit
4 digits LCD display
Analog BNC output
Available AD data acquisition system for capture to computer
Cooling temperature: -20°C. Warm-up time 10 minutes
Note: Cooling temperature is dependent on ambient temperature
Includes a small water recirculator (required for operation)
6,697.00
Integral HV power supply and display unit
4 digits LCD display
Analog BNC output
Available AD data acquisition system for capture to computer
Cooling temperature: -20°C. Warm-up time 10 minutes
Note: Cooling temperature is dependent on ambient temperature
Includes a small water recirculator (required for operation)
6,697.00 6697.0 USD
Price Valid only in North America


Sciencetech's proprietary wideband detector design comes packaged in our standard "hockey puck" enclosure (2" diameter x 1" high) and is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers,
The spectral range is limited by high density polyethylene window.
The detector WILL saturate on the visible light from the lamp. After alignment, cover the entire input opening of the detector head with thin black polyethylene to prevent undesired visible light from overloading the detector.
This detector is suitable for direct connection to Stanford SR-830 lockin preamp power. When using the Stanford lock-in, the signal overload indicator will light just before the detector saturates.The SCIDTGS-PE detector is suitable for testing FTIR alignment and material transmission measurements without special cooling.
Upon installation, the optical system MUST be re-aligned to image the iris of the light source onto the detector element. This may require rotating the entire detector head to an optimum position and/or adjusting mirrors and re-focusing.
Element size 2.0 mm dia.
Spectral bandwidth Limited by High Density Polyethylene window
Sensitivity 133,000 volts per watt HDPE Window
Frequency response 8.8Hz - 265Hz (-3db points)
N.E.P. 1x10-10 watts (100Hz, 1Hz BW)

Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections: DB-9M Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Suitable for direct connection to Stanford SR-830 lockin preamp power (not included).
6,200.00
In stock
Sciencetech's proprietary wideband detector design comes packaged in our standard "hockey puck" enclosure (2" diameter x 1" high) and is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers,
The spectral range is limited by high density polyethylene window.
The detector WILL saturate on the visible light from the lamp. After alignment, cover the entire input opening of the detector head with thin black polyethylene to prevent undesired visible light from overloading the detector.
This detector is suitable for direct connection to Stanford SR-830 lockin preamp power. When using the Stanford lock-in, the signal overload indicator will light just before the detector saturates.The SCIDTGS-PE detector is suitable for testing FTIR alignment and material transmission measurements without special cooling.
Upon installation, the optical system MUST be re-aligned to image the iris of the light source onto the detector element. This may require rotating the entire detector head to an optimum position and/or adjusting mirrors and re-focusing.
Element size 2.0 mm dia.
Spectral bandwidth Limited by High Density Polyethylene window
Sensitivity 133,000 volts per watt HDPE Window
Frequency response 8.8Hz - 265Hz (-3db points)
N.E.P. 1x10-10 watts (100Hz, 1Hz BW)

Power requirements: +/- 15 to +/- 24 volts max @ +/- 8 mA max.
Power connections: DB-9M Pins 2,3,4,5,9 no connection
+V In Pin 1
-V In Pin 6
Common Pin 7
Case GND Pin 8
Suitable for direct connection to Stanford SR-830 lockin preamp power (not included).
6,200.00 6200.0 USD
Price Valid only in North America


The Sciencetech PMH-01 Photon Counting Module is self-contained compact unit incorporating PMT tube, high-speed amplifier, discriminator, and high voltage power supply. The output signal (train of pulses, the number of which corresponds to the number of detected photons) can be sent via a BNC connector, to an external counting/displaying circuit. The PMH-01 outputs digital signal (pulses) only. There is no analog output port.

The photon counting head used has low power consumption (max 0.5W). It is already adjusted for best S/N ratio. There is no additional adjustment necessary to start the operation.

Parameter Value
Operating Temperature Range +5 to + 40 °C
Storage Temperature Range -20 to +50 °C
Effective Area 4 x 6 sq.mm
Spectral Response 185 to 900 nm
Dark Count (Typical) 400 cps
Dark Count (Max.) 800 cps
Counting Linearity 2.5 Mcps
Pulse Pair Resolution 35 ns
Output Pulse Width 30 ns
Output Logic TTL, positive
Input Voltage +5 V
Input Current at 2.5 Mcps Output max. 80 mA
Output Signal Cable RG-174/U
4,000.00
In stock
The Sciencetech PMH-01 Photon Counting Module is self-contained compact unit incorporating PMT tube, high-speed amplifier, discriminator, and high voltage power supply. The output signal (train of pulses, the number of which corresponds to the number of detected photons) can be sent via a BNC connector, to an external counting/displaying circuit. The PMH-01 outputs digital signal (pulses) only. There is no analog output port.

The photon counting head used has low power consumption (max 0.5W). It is already adjusted for best S/N ratio. There is no additional adjustment necessary to start the operation.

Parameter Value
Operating Temperature Range +5 to + 40 °C
Storage Temperature Range -20 to +50 °C
Effective Area 4 x 6 sq.mm
Spectral Response 185 to 900 nm
Dark Count (Typical) 400 cps
Dark Count (Max.) 800 cps
Counting Linearity 2.5 Mcps
Pulse Pair Resolution 35 ns
Output Pulse Width 30 ns
Output Logic TTL, positive
Input Voltage +5 V
Input Current at 2.5 Mcps Output max. 80 mA
Output Signal Cable RG-174/U
4,000.00 4000.0 USD
Price Valid only in North America


Photon counting head using 28mm dia. Side on PMT. Spectral response range 185nm - 850nm. Low dark counts in UV to near IR range.
For full technical specifications, please contact your authorized Sciencetech technical sales staff member.
3,663.00
Photon counting head using 28mm dia. Side on PMT. Spectral response range 185nm - 850nm. Low dark counts in UV to near IR range.
For full technical specifications, please contact your authorized Sciencetech technical sales staff member.
3,663.00 3663.0 USD
Price Valid only in North America


Main Features:

Lithium tantalate sensor
Compatible with EOS PS-1 power supply or EOS LIA/PS-1 lock-in/power supply
Power requirements are ±15 volts to ± 24 volts at ± 5mA max.
Quartz or fused silica window allows essentially flat response (±3%) 300nm-2.1µm
Electrical response -3dB points typically 0.5Hz - 150Hz
Saturation Power: 30mW

Optional Features

Sapphire, germanium, silicon, CaF2, BaF2, or KBr windows are available instead of quartz at extra cost, please specify when ordering
Specialized calibration options at extra cost, please speak to a Sciencetech representative or write to sales@sciencetech-inc.com
Lockin module (price not included in standard detector package)
3,230.00
In stock
Main Features:

Lithium tantalate sensor
Compatible with EOS PS-1 power supply or EOS LIA/PS-1 lock-in/power supply
Power requirements are ±15 volts to ± 24 volts at ± 5mA max.
Quartz or fused silica window allows essentially flat response (±3%) 300nm-2.1µm
Electrical response -3dB points typically 0.5Hz - 150Hz
Saturation Power: 30mW

Optional Features

Sapphire, germanium, silicon, CaF2, BaF2, or KBr windows are available instead of quartz at extra cost, please specify when ordering
Specialized calibration options at extra cost, please speak to a Sciencetech representative or write to sales@sciencetech-inc.com
Lockin module (price not included in standard detector package)
3,230.00 3230.0 USD
Price Valid only in North America


Sciencetech's proprietary wideband detector design comes packaged in our standard "hockey puck" enclosure (2" diameter x 1" high) and is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers and optimized to utilize the full input range of these
lock-ins for FTIR applications.
Features of our SCI425CMB0:
This detector is not hygroscopic and may be operated indefinitely under normal atmospheric conditions and at temperatures beyond 100oC. A selection of windows is available to limit spectral response.
3,200.00
In stock
Sciencetech's proprietary wideband detector design comes packaged in our standard "hockey puck" enclosure (2" diameter x 1" high) and is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers and optimized to utilize the full input range of these
lock-ins for FTIR applications.
Features of our SCI425CMB0:
This detector is not hygroscopic and may be operated indefinitely under normal atmospheric conditions and at temperatures beyond 100oC. A selection of windows is available to limit spectral response.
3,200.00 3200.0 USD
Price Valid only in North America


This is an H-Series pyroelectric / receiver, specifically for the 10 kHz Bandwidth. Comes with sapphire windows by default (good between 500nm to 6 microns, approximately). Various other windows are available at extra cost: please ask you Sciencetech Representative.
3,000.00
This is an H-Series pyroelectric / receiver, specifically for the 10 kHz Bandwidth. Comes with sapphire windows by default (good between 500nm to 6 microns, approximately). Various other windows are available at extra cost: please ask you Sciencetech Representative.
3,000.00 3000.0 USD
Price Valid only in North America


Element Size: 1mm x 1mm sq.
Operating Wavelength: 2 – 13um
Wavelength Peak: ~12.0um
Wavelength Response: >= 13.0um (750cm-1)
D* (λp,10000,1) (cmHz1/2W-1): >= 4.0^10
Dewar Hold Time: 12 hours minimum with liquid N2
FoV/Window: 60 degrees/ ZnSe
Responsivity: >= 2000 (pk. (V/W))
Resistance: 20-100 ohms
Time Constant: ~1.0 usec
MSL-8 side looking metal Dewar 8 hour hold time
2,935.00
In stock
Element Size: 1mm x 1mm sq.
Operating Wavelength: 2 – 13um
Wavelength Peak: ~12.0um
Wavelength Response: >= 13.0um (750cm-1)
D* (λp,10000,1) (cmHz1/2W-1): >= 4.0^10
Dewar Hold Time: 12 hours minimum with liquid N2
FoV/Window: 60 degrees/ ZnSe
Responsivity: >= 2000 (pk. (V/W))
Resistance: 20-100 ohms
Time Constant: ~1.0 usec
MSL-8 side looking metal Dewar 8 hour hold time
2,935.00 2935.0 USD
Price Valid only in North America


Sciencetech's proprietary wideband detector design comes packaged in our standard "hockey puck" enclosure (2" diameter x 1" high) and is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers and optimized to utilize the full input range of these lock-ins as a reference detector for Spectral Response, Quantum Efficiency, Constant Photocurrent Measurement in Photovoltaic Testing Systems.
Features of our SCI425CMA:
This detector is not hygroscopic and may be operated indefinitely under normal atmospheric conditions and at temperatures beyond 100oC. A selection of windows is available to limit spectral response.
Calibration is supplied with the detector.
Element size: 5 mm dia.
Spectral response: (no window, blackened): 180nm – 2.5 microns (Quartz Window)
2,400.00
In stock
Sciencetech's proprietary wideband detector design comes packaged in our standard "hockey puck" enclosure (2" diameter x 1" high) and is connectorized to be powered directly from the Stanford SR-810/830 type lock-in amplifiers and optimized to utilize the full input range of these lock-ins as a reference detector for Spectral Response, Quantum Efficiency, Constant Photocurrent Measurement in Photovoltaic Testing Systems.
Features of our SCI425CMA:
This detector is not hygroscopic and may be operated indefinitely under normal atmospheric conditions and at temperatures beyond 100oC. A selection of windows is available to limit spectral response.
Calibration is supplied with the detector.
Element size: 5 mm dia.
Spectral response: (no window, blackened): 180nm – 2.5 microns (Quartz Window)
2,400.00 2400.0 USD
Price Valid only in North America


4 digits LCD displays high voltage output signal
BNC analog signal ouput
External high voltage control for the PMT (for computer control)
Six time constants switchable from a front panel control (from .01ms to 1sec.)
Zero adjustment control to cancel the effect of dark current and stray light
Adjustable gain 1, 10, 100 and 1,000 X
Includes power supply.
2,398.00
In stock
4 digits LCD displays high voltage output signal
BNC analog signal ouput
External high voltage control for the PMT (for computer control)
Six time constants switchable from a front panel control (from .01ms to 1sec.)
Zero adjustment control to cancel the effect of dark current and stray light
Adjustable gain 1, 10, 100 and 1,000 X
Includes power supply.
2,398.00 2398.0 USD
Price Valid only in North America


A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 930nm.

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
2,170.00
In stock
A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 930nm.

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
2,170.00 2170.0 USD
Price Valid only in North America


28 mm (1-1/8 inch) transmission mode S-1 photocathode, Side-on type.
Spectral Response: 400 - 1200nm
Wavelength of Maximum Response: 800nm
Minimum Effective Area (HxW): 16 x 18

Quantum Efficiency (at 25 degrees): 0.04% (Typical)
Anode Dark Current (after 30 min storage in darkness): 350 (typical), 1000 (max) nA
1,946.00
In stock
28 mm (1-1/8 inch) transmission mode S-1 photocathode, Side-on type.
Spectral Response: 400 - 1200nm
Wavelength of Maximum Response: 800nm
Minimum Effective Area (HxW): 16 x 18

Quantum Efficiency (at 25 degrees): 0.04% (Typical)
Anode Dark Current (after 30 min storage in darkness): 350 (typical), 1000 (max) nA
1,946.00 1946.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00
In stock
This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00 1727.0 USD
Price Valid only in North America


This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.
The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a calibrated solar detector made of silicon.
The Reference Detector comes with calibration data taken by Sciencetech, calibrating it to a NIST-certified solar cell, on an accompanying certificate. It reads solar simulator irradiance in "sun" units; one sun is equal to 1,000 W/m^2, at 25 degrees Celsius and Air Mass 1.5 Global.
This tool's primary use is the testing of photovoltaic cells under standard conditions.
1,675.00
In stock
This product consists of the Sciencetech SOL-METER and our SSIVT-REF sun calibrated reference detector. The SOL-METER is a digital meter for use with solar calibrated detectors such as detector models SSIVT-REF or SC-LT. The meter converts detector measurements to a Sun value. It has a handheld meter that is compact, has a sturdy design, and is appropriate for indoor or outdoor applications.
The Sciencetech Reference Detector, which is an integral part of solar simulator calibration and solar cell I-V characterization, consists of a calibrated solar detector made of silicon.
The Reference Detector comes with calibration data taken by Sciencetech, calibrating it to a NIST-certified solar cell, on an accompanying certificate. It reads solar simulator irradiance in "sun" units; one sun is equal to 1,000 W/m^2, at 25 degrees Celsius and Air Mass 1.5 Global.
This tool's primary use is the testing of photovoltaic cells under standard conditions.
1,675.00 1675.0 USD
Price Valid only in North America