Sciencetech has a large selection of "stand alone" and "open architecture" off-the-shelf and custom made products for researchers using spectroscopy or working with photovoltaics. We offer technical staff to help with the development of custom systems for special applications. Since 1985, Sciencetech has manufactured Modular Instrumentation for Spectroscopy, TeraHertz FTIRs, Highly Collimated Large Solar Simulators, Flash and Continuous Solar Simulators, Photovoltaic Instrumentation, Quantum Efficiency and Spectral Response Systems, Spectrophotometers/radiometers, Monochromators, Detection Systems, and Light Sources to offer to the global research community through a network of representatives.

 here

Sciencetech product design

SCIENCETECH has built a reputation on custom solutions. Whether you need a small modification to an existing system or a completely novel design built from the ground up to meet your technical specifications, Sciencetech's optical, mechanical, and electrical design teams are ready to help.

SCIENCETECH prides itself on our ability to build custom solutions and systems to the most exacting of specifications. Whether you need higher sensitivity, better throughput, more power, better spectral matching, higher resolution, or any other variable modified to give you exactly what you need, our team of physicists, technicians, and optical designers stand ready to provide you with a solution that will meet your technical requirements.

SCIENCETECH'S SOLAR SIMULATORS IN ACTION - The European Commission just released an article involving the use of Sciencetech's solar simulators in their new facility. Read the full article HERE.

X

Product Category

View Filter

x
Clear all x

Filter Option



This is a single fixed width slit for Sciencetech's monochromators. It requires a SS-F slit holder (120-9046) for each input/output. Multiple slits can be exchanged using a single slit holder.
The slit height is 8mm. The slit width is 1mm.
253.00
In Stock
This is a single fixed width slit for Sciencetech's monochromators. It requires a SS-F slit holder (120-9046) for each input/output. Multiple slits can be exchanged using a single slit holder.
The slit height is 8mm. The slit width is 1mm.
253.00 253.0 USD

Price valid only in North America


This is a single fixed width slit for Sciencetech's monochromators. It requires a SS-F slit holder (120-9046) for each input/output. Multiple slits can be exchanged using a single slit holder.
The slit height is 8mm. The slit width is 2mm.
253.00
In Stock
This is a single fixed width slit for Sciencetech's monochromators. It requires a SS-F slit holder (120-9046) for each input/output. Multiple slits can be exchanged using a single slit holder.
The slit height is 8mm. The slit width is 2mm.
253.00 253.0 USD

Price valid only in North America


Blue, 72mm diameter filter, including holder.
Please speak with your authorized Sciencetech technical sales staff member for additional information.
In Stock
Blue, 72mm diameter filter, including holder.
Please speak with your authorized Sciencetech technical sales staff member for additional information.
263.00 263.0 USD


Red, 72mm diameter filter, including holder.
Please speak with your authorized Sciencetech technical sales staff member for additional information.
In Stock
Red, 72mm diameter filter, including holder.
Please speak with your authorized Sciencetech technical sales staff member for additional information.
263.00 263.0 USD


Green, 72mm diameter filter, including holder.
Please speak with your authorized Sciencetech technical sales staff member for additional information.
In Stock
Green, 72mm diameter filter, including holder.
Please speak with your authorized Sciencetech technical sales staff member for additional information.
263.00 263.0 USD


The IRE-12 a coiled filament operating at approximately 900 degrees Celsius when powered with 10 watts. The radiating element is a coil of resistance wire which has a high emissivity in the Infrared spectral region. The coil is supported by a grooved cylindrical substrate of alumina, resulting in the windings being electrically insulated from each other. This contributes to a more uniform radiating source. The unit does not require operation in a sealed atmosphere. The header is fabricated from cold-rolled steel. The support pins are hermetically sealed in glass.
266.00
In Stock
The IRE-12 a coiled filament operating at approximately 900 degrees Celsius when powered with 10 watts. The radiating element is a coil of resistance wire which has a high emissivity in the Infrared spectral region. The coil is supported by a grooved cylindrical substrate of alumina, resulting in the windings being electrically insulated from each other. This contributes to a more uniform radiating source. The unit does not require operation in a sealed atmosphere. The header is fabricated from cold-rolled steel. The support pins are hermetically sealed in glass.
266.00 266.0 USD

Price valid only in North America


This holder is economical choice for slits for Sciencetech monochromators such as the 9055.
This slit holder is required when using FWS-series fixed slits (Product Numbers 120-9010, 120-9011, 120-9012, 120-9013, 120-9033, and 120-9034).

Only one slit holder is required per input/output; different slits can be exchanged using the same slit holder. Please add the size of slit you would like to the order. Sizes are available from 0.05 mm (50 um) up to 3 mm. Slits are 8 mm tall.
In Stock
This holder is economical choice for slits for Sciencetech monochromators such as the 9055.
This slit holder is required when using FWS-series fixed slits (Product Numbers 120-9010, 120-9011, 120-9012, 120-9013, 120-9033, and 120-9034).

Only one slit holder is required per input/output; different slits can be exchanged using the same slit holder. Please add the size of slit you would like to the order. Sizes are available from 0.05 mm (50 um) up to 3 mm. Slits are 8 mm tall.
288.00 288.0 USD


This optical coupler can be used to couple beam line components and allows for independent adjustment of +-3mm along each of two orthogonal axis. This coupler is intended to mate one end to either a 1-D or 4S connection. The other end accepts any component with a 1.035-40 thread. With the CON1-XY-T1 the optical alignment of optical elements such as optical fibers can be optimized to monochromator input slits or target locations.

In Stock
This optical coupler can be used to couple beam line components and allows for independent adjustment of +-3mm along each of two orthogonal axis. This coupler is intended to mate one end to either a 1-D or 4S connection. The other end accepts any component with a 1.035-40 thread. With the CON1-XY-T1 the optical alignment of optical elements such as optical fibers can be optimized to monochromator input slits or target locations.

302.00 302.0 USD


Neutral density wire mesh filter, transmitting a percentage of incident light, mounted in an FT style holder. These filters are robust to high-powered applications (such as solar simulation), do not affect the non-uniformity of the target, and transmission is spectrally flat. Please select the desired transmission percentage for your application.

Each filter is mounted in an FT-style filter holder.
Each filter has a 73 mm clear aperture.
333.00
Neutral density wire mesh filter, transmitting a percentage of incident light, mounted in an FT style holder. These filters are robust to high-powered applications (such as solar simulation), do not affect the non-uniformity of the target, and transmission is spectrally flat. Please select the desired transmission percentage for your application.

Each filter is mounted in an FT-style filter holder.
Each filter has a 73 mm clear aperture.
333.00 333.0 USD

Price valid only in North America


This option adds an additional 2 filter positions to the FH-SS filter holder. The FH-SS and FH-SS-ADD option are designed to be used with Sciencetech FT-75-3 type blank filter holders as well as filters that include the -FT option. The FH-SS filter holder is used with Sciencetech's line of Fully Reflective solar simulators as well as the Solar Lightline and SciSun solar simulators.
354.00
This option adds an additional 2 filter positions to the FH-SS filter holder. The FH-SS and FH-SS-ADD option are designed to be used with Sciencetech FT-75-3 type blank filter holders as well as filters that include the -FT option. The FH-SS filter holder is used with Sciencetech's line of Fully Reflective solar simulators as well as the Solar Lightline and SciSun solar simulators.
354.00 354.0 USD

Price valid only in North America


This filter set consists of three wire-mesh neutral-density filters to be installed in the filter wheel. This filter set is designed to be used with the Sciencetech's Solar Lightline fiber-based solar simulator. Optical density of each filter is selected such that the final beam output from the light guide and collimator will be selectable at 0.25, 0.5, 0.75 and 1 of maximum irradiance for the AX Lightline system.
In Stock
This filter set consists of three wire-mesh neutral-density filters to be installed in the filter wheel. This filter set is designed to be used with the Sciencetech's Solar Lightline fiber-based solar simulator. Optical density of each filter is selected such that the final beam output from the light guide and collimator will be selectable at 0.25, 0.5, 0.75 and 1 of maximum irradiance for the AX Lightline system.
354.00 354.0 USD


Set of 6 optical density filters in values of 0.15, 0.3, 0.4, 0.6, 0.9, and 2.5. Each is 25 mm diameter and unmounted; the filter wheel is sold separately.
These are absorption filters and should not be used for high-powered applications (as opposed to reflective neutral density).
In Stock
Set of 6 optical density filters in values of 0.15, 0.3, 0.4, 0.6, 0.9, and 2.5. Each is 25 mm diameter and unmounted; the filter wheel is sold separately.
These are absorption filters and should not be used for high-powered applications (as opposed to reflective neutral density).
354.00 354.0 USD


A sample platform designed to operate for any of Sciencetech's line of Fully Reflective solar simulators. The sample tray is intended to be used with SS0.5k-SS1.6k simulators with downward facing beams. For a complete downward facing package for your SS0.5k-SS10.6k fully reflective solar simulator please see product (DFS-SS).
This sample platform includes a clamp for maintaining its position. The sample platform can be used to mount a variety of cell chucks offered by Sciencetech. Please speak with your authorized Sciencetech technical sales staff member to discuss cell chucks, probes, vacuum, or water cooling options.
In Stock
A sample platform designed to operate for any of Sciencetech's line of Fully Reflective solar simulators. The sample tray is intended to be used with SS0.5k-SS1.6k simulators with downward facing beams. For a complete downward facing package for your SS0.5k-SS10.6k fully reflective solar simulator please see product (DFS-SS).
This sample platform includes a clamp for maintaining its position. The sample platform can be used to mount a variety of cell chucks offered by Sciencetech. Please speak with your authorized Sciencetech technical sales staff member to discuss cell chucks, probes, vacuum, or water cooling options.
354.00 354.0 USD


This upgrade is for Sciencetech's High Resolution line of monochromators, including the 9040, 9490, and 9150 (for both the single and double pass options for those systems). It moves the output port from the front of the monochromator to the side or lateral position. This allows different orientations of the system in relation to various sample chambers or detectors, and may be required depending on the size of the detector you are using due to the close proximity and limited space between the input and output slit on the front plate.
Please note that this upgrade does not allow both output ports to be used; it only moves the default output from the front of the system to the side. If you require both output ports be usable, please see DPOUT-HI products.
This upgrade is for Sciencetech's High Resolution line of monochromators, including the 9040, 9490, and 9150 (for both the single and double pass options for those systems). It moves the output port from the front of the monochromator to the side or lateral position. This allows different orientations of the system in relation to various sample chambers or detectors, and may be required depending on the size of the detector you are using due to the close proximity and limited space between the input and output slit on the front plate.
Please note that this upgrade does not allow both output ports to be used; it only moves the default output from the front of the system to the side. If you require both output ports be usable, please see DPOUT-HI products.
368.00 368.0 USD


The SCI-MO reference cell is a robust PCB-mounted solar cell with an active area of 22 × 7 mm. The SCI-MO is intended to be used as a reference monitor for determining solar simulator sun level. These reference cells are calibrated for 1 Sun AM1.5G using a Sciencetech Class AAA (ASTM E927-19) solar simulator. Two calibration values (Isc) in mA/Sun and mV/Sun are provided. The SCI-MO is used as the reference cell in PTS-series instruments.

Measurement Range: 0.1 to 2 Suns AM1.5G.

Readout options for the SCI-MO require accessories. They are:
Current (in mA): in no load mode, requires a source meter (such as in SSIVT-series current-voltage measurement systems) to read out.
Voltage (in mV): in loaded mode, requires a simple voltmeter/multimeter (such as MULTIMETER), or a source meter (such as in SSIVT-series current-voltage measurement systems) to read out.
Suns: in no load mode, requires SOL-METER to read out (using current, an integrated load resistor, and a pre-loaded calibration value to display Suns).

Readout accessories, such as SOL-METER, MULTIMETER, and SSIVT-series instruments are sold separately.

The reference cell can be switched into loaded or unloaded mode via a surface mounted switch on the top of the detector PCB. A calibration value is provided for each mode of operation.
A disconnectable 1.2m long cable assembly with 4 color coded banana plugs is provided with each device.

The SCI-MO reference cell is RoHS compliant.
383.00
The SCI-MO reference cell is a robust PCB-mounted solar cell with an active area of 22 × 7 mm. The SCI-MO is intended to be used as a reference monitor for determining solar simulator sun level. These reference cells are calibrated for 1 Sun AM1.5G using a Sciencetech Class AAA (ASTM E927-19) solar simulator. Two calibration values (Isc) in mA/Sun and mV/Sun are provided. The SCI-MO is used as the reference cell in PTS-series instruments.

Measurement Range: 0.1 to 2 Suns AM1.5G.

Readout options for the SCI-MO require accessories. They are:
Current (in mA): in no load mode, requires a source meter (such as in SSIVT-series current-voltage measurement systems) to read out.
Voltage (in mV): in loaded mode, requires a simple voltmeter/multimeter (such as MULTIMETER), or a source meter (such as in SSIVT-series current-voltage measurement systems) to read out.
Suns: in no load mode, requires SOL-METER to read out (using current, an integrated load resistor, and a pre-loaded calibration value to display Suns).

Readout accessories, such as SOL-METER, MULTIMETER, and SSIVT-series instruments are sold separately.

The reference cell can be switched into loaded or unloaded mode via a surface mounted switch on the top of the detector PCB. A calibration value is provided for each mode of operation.
A disconnectable 1.2m long cable assembly with 4 color coded banana plugs is provided with each device.

The SCI-MO reference cell is RoHS compliant.
383.00 383.0 USD

Price valid only in North America


This accessory is a base and post assembly designed to work with 2" diameter optical assemblies. The PM90 allows a 2" optical assembly to be held vertically or horizontally and rotated through any angle, and is adjustable to any height above the included base plate from 0 to 12". The included 6x12" base plate can be secured to a standard optical table or left free standing. This accessory can be used with Sciencetech's AX Solar LightLine solar simulators to allow for horizontal or vertical operation (and at any angle) by holding to output optic at the end of the 4 foot light guide.
This accessory is a base and post assembly designed to work with 2" diameter optical assemblies. The PM90 allows a 2" optical assembly to be held vertically or horizontally and rotated through any angle, and is adjustable to any height above the included base plate from 0 to 12". The included 6x12" base plate can be secured to a standard optical table or left free standing. This accessory can be used with Sciencetech's AX Solar LightLine solar simulators to allow for horizontal or vertical operation (and at any angle) by holding to output optic at the end of the 4 foot light guide.
404.00 404.0 USD


This high-powered filter blocks UV light below 320 nm. This filter is designed for 0 degree angle of incidence. This filter is mounted in a FT style filter holder and has a clear aperture of 73 mm diameter.
404.00
In Stock
This high-powered filter blocks UV light below 320 nm. This filter is designed for 0 degree angle of incidence. This filter is mounted in a FT style filter holder and has a clear aperture of 73 mm diameter.
404.00 404.0 USD

Price valid only in North America


Sciencetech's FB1T filter box holds one filter per filter box and can accommodate up to 3" x 3" filters. The FB1T filter box is used to stop back reflections from travelling along the path of the incident light. The FB1T filter boxes are stackable, so multiple FB1T filter boxes can be attached if using more than one filter at once is required.
The FB1T has standard mounting for slip rings that are compatible with 2" diameter lens tubes.
For mounting with 1" diameter lens tubes Sciencetech's S4-1D (100-8038) coupling adaptor is required.

No filter holders are included and filter holders are dependent on the size of the filters to be used.

Compatible filter holders are the FT-series (e.g. FT-75).
414.00
Sciencetech's FB1T filter box holds one filter per filter box and can accommodate up to 3" x 3" filters. The FB1T filter box is used to stop back reflections from travelling along the path of the incident light. The FB1T filter boxes are stackable, so multiple FB1T filter boxes can be attached if using more than one filter at once is required.
The FB1T has standard mounting for slip rings that are compatible with 2" diameter lens tubes.
For mounting with 1" diameter lens tubes Sciencetech's S4-1D (100-8038) coupling adaptor is required.

No filter holders are included and filter holders are dependent on the size of the filters to be used.

Compatible filter holders are the FT-series (e.g. FT-75).
414.00 414.0 USD

Price valid only in North America


This is an upgrade to Sciencetech's High Resolution monochromators, including the 9040, 9490, and 9150 (for both the Single and Double Pass configurations of these systems). It moves the input slit from the default position on the front of the monochromator to the side or lateral position.
Please note that this upgrade does not allow both input ports to be used, it only moves the position. If you require both input ports and the flipping mirror to select between them, please see DPIN-HI products.
This is an upgrade to Sciencetech's High Resolution monochromators, including the 9040, 9490, and 9150 (for both the Single and Double Pass configurations of these systems). It moves the input slit from the default position on the front of the monochromator to the side or lateral position.
Please note that this upgrade does not allow both input ports to be used, it only moves the position. If you require both input ports and the flipping mirror to select between them, please see DPIN-HI products.
453.00 453.0 USD



Hand held UV Radiometer.
Irrad. Range 19.99 W/m2 Ery
Response 280-400 nm Diffey Erythermal Action Spectrum
Resolution 0.01 W/m2
Conv. Rate 3.0 Readings/Sec
Display 3.5 Digit LCD
Digit Size 0.4 inch high
Oper. Temp 32° F TO100° F
Oper. Humid. 5% TO 80% RH
Accuracy ±10% REF.NIST
Dimensions (in.) 4.2L x 2.4W x 0.9D (inches)
Weight 4.5 OZ. (incl. batt.)
Power Source 9-Volt DC Battery
Lens UV Glass
Diffuser Teflon
Detector SIC/IF Photodiode

Hand held UV Radiometer.
Irrad. Range 19.99 W/m2 Ery
Response 280-400 nm Diffey Erythermal Action Spectrum
Resolution 0.01 W/m2
Conv. Rate 3.0 Readings/Sec
Display 3.5 Digit LCD
Digit Size 0.4 inch high
Oper. Temp 32° F TO100° F
Oper. Humid. 5% TO 80% RH
Accuracy ±10% REF.NIST
Dimensions (in.) 4.2L x 2.4W x 0.9D (inches)
Weight 4.5 OZ. (incl. batt.)
Power Source 9-Volt DC Battery
Lens UV Glass
Diffuser Teflon
Detector SIC/IF Photodiode
455.00 455.0 USD
Copyright © Sciencetech