A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 900nm.
Special feature: extra low dark current, transit time 22ns
input window: 6x8 mm

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
1,020.00
In Stock
A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 900nm.
Special feature: extra low dark current, transit time 22ns
input window: 6x8 mm

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
1,020.00 1020.0 USD
Price Valid only in North America

The Sciencetech SSIVT-REF single element silicon detector is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated to the NIST traceable calibrated reference cell. The SSIVT-REF detector can be used with Sciencetech SSIVT measurement system or Sciencetech SOL-METER solar power meter.


Rise time: 0.2 μs
Effective active area: 5.7 sqmm
625.00
In Stock
The Sciencetech SSIVT-REF single element silicon detector is designed to be used for monitoring and verifying the Sun level of solar simulators. The SSIVT-REF detector is used effective in sensing wavelengths between 190 nm and 1100 nm and is calibrated to the NIST traceable calibrated reference cell. The SSIVT-REF detector can be used with Sciencetech SSIVT measurement system or Sciencetech SOL-METER solar power meter.


Rise time: 0.2 μs
Effective active area: 5.7 sqmm
625.00 625.0 USD
Price Valid only in North America

This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00
In Stock
This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00 1727.0 USD
Price Valid only in North America

This single element detector is effective at sensing wavelengths between 2,000nm and 15,000nm. Please note that it is available in various sizes and includes a dewar to hold liquid nitrogen (to lower dark current and improved signal to noise). To operate this detector liquid nitrogren is required. As with most IR detectors MCT detectors are coupled to AC preamplifiers which means they detect changes in light levels. Generally the light signal being detected is modulated with a chopper or the source itself is modulated, such as a pulsed laser source. When using a chopper to modulate the input signal generally a lock-in amplifier is used to demodulate the signal. The output signal from the MCT is an analog signal available through a BNC on the back of the detector housing. Since the signal is analog, an optional 12-bit or 16-bit data acquistion system and software is available (sold separately).
The MCT detector includes a preamplier. This system also requires a power supply (sold separately, compatible with the PS-1/LIA 590-0106 or PS-1 590-0006 when another lock in amplifier is used).
To connect this detector to a Sciencetech monochromator use the cryogenic detector mount P/# 125-8016
2,520.00
In Stock
This single element detector is effective at sensing wavelengths between 2,000nm and 15,000nm. Please note that it is available in various sizes and includes a dewar to hold liquid nitrogen (to lower dark current and improved signal to noise). To operate this detector liquid nitrogren is required. As with most IR detectors MCT detectors are coupled to AC preamplifiers which means they detect changes in light levels. Generally the light signal being detected is modulated with a chopper or the source itself is modulated, such as a pulsed laser source. When using a chopper to modulate the input signal generally a lock-in amplifier is used to demodulate the signal. The output signal from the MCT is an analog signal available through a BNC on the back of the detector housing. Since the signal is analog, an optional 12-bit or 16-bit data acquistion system and software is available (sold separately).
The MCT detector includes a preamplier. This system also requires a power supply (sold separately, compatible with the PS-1/LIA 590-0106 or PS-1 590-0006 when another lock in amplifier is used).
To connect this detector to a Sciencetech monochromator use the cryogenic detector mount P/# 125-8016
2,520.00 2520.0 USD
Price Valid only in North America

This single element detector is effective at sensing wavelengths between 2,000nm and 12,000nm. Please note that it is available in various sizes and includes a dewar to hold liquid nitrogen (to lower dark current and improved signal to noise). To operate this detector liquid nitrogren is required. As with most IR detectors MCT detectors are coupled to AC preamplifiers which means they detect changes in light levels. Generally the light signal being detected is modulated with a chopper or the source itself is modulated, such as a pulsed laser source. When using a chopper to modulate the input signal generally a lock-in amplifier is used to demodulate the signal. The output signal from the MCT is an analog signal available through a BNC on the back of the detector housing. Since the signal is analog, an optional 12-bit or 16-bit data acquistion system and software is available (sold separately).
The MCT detector includes a preamplier. This system also requires a power supply (sold separately, compatible with the PS-1/LIA 590-0106 or PS-1 590-0006 when another lock in amplifier is used).
To connect this detector to a Sciencetech monochromator use the cryogenic detector mount P/# 125-8016
2,835.00
In Stock
This single element detector is effective at sensing wavelengths between 2,000nm and 12,000nm. Please note that it is available in various sizes and includes a dewar to hold liquid nitrogen (to lower dark current and improved signal to noise). To operate this detector liquid nitrogren is required. As with most IR detectors MCT detectors are coupled to AC preamplifiers which means they detect changes in light levels. Generally the light signal being detected is modulated with a chopper or the source itself is modulated, such as a pulsed laser source. When using a chopper to modulate the input signal generally a lock-in amplifier is used to demodulate the signal. The output signal from the MCT is an analog signal available through a BNC on the back of the detector housing. Since the signal is analog, an optional 12-bit or 16-bit data acquistion system and software is available (sold separately).
The MCT detector includes a preamplier. This system also requires a power supply (sold separately, compatible with the PS-1/LIA 590-0106 or PS-1 590-0006 when another lock in amplifier is used).
To connect this detector to a Sciencetech monochromator use the cryogenic detector mount P/# 125-8016
2,835.00 2835.0 USD
Price Valid only in North America

28 mm (1-1/8 inch) transmission mode S-1 photocathode, Side-on type.
Spectral Response: 400 - 1200nm
Wavelength of Maximum Response: 800nm
Minimum Effective Area (HxW): 16 x 18

Quantum Efficiency (at 25 degrees): 0.04% (Typical)
Anode Dark Current (after 30 min storage in darkness): 350 (typical), 1000 (max) nA
1,946.00
In Stock
28 mm (1-1/8 inch) transmission mode S-1 photocathode, Side-on type.
Spectral Response: 400 - 1200nm
Wavelength of Maximum Response: 800nm
Minimum Effective Area (HxW): 16 x 18

Quantum Efficiency (at 25 degrees): 0.04% (Typical)
Anode Dark Current (after 30 min storage in darkness): 350 (typical), 1000 (max) nA
1,946.00 1946.0 USD
Price Valid only in North America

Multialkali high sensitivity side-on PMT
Spectral range: 185-900 nm,
Peak sensitivity wavelength: 400nm
Glass UV Envelope

Photocathode Area Size 8 x 24 mm
Photocathode Material Multialkali
Window Material UV glass
Dynode Structure Circular-cage
Anode to Cathode Voltage 1250 V
Average Anode Current 0.1 mA
Anode to Cathode Supply Voltage 1000 V
Luminous Sensitivity Min. 140 μA/lm
Luminous Sensitivity Typ. 250 μA/lm
Radiant Sensitivity Typ. 74 mA/W
Anode Luminous Sensitivity Min. 400 A/lm
Anode Luminous Sensitivity Typ. 2500 A/lm
Anode Radiant Sensitivity Typ. 7.4e5 A/W
Anode Dark Current (after 30min.) Typ. 3 nA
Anode Dark Current (after 30min.) Max. 50 nA
Time Response Rise Time Typ. 2.2 ns
Time Response Transit Time Typ. 22 ns
1,004.00
In Stock
Multialkali high sensitivity side-on PMT
Spectral range: 185-900 nm,
Peak sensitivity wavelength: 400nm
Glass UV Envelope

Photocathode Area Size 8 x 24 mm
Photocathode Material Multialkali
Window Material UV glass
Dynode Structure Circular-cage
Anode to Cathode Voltage 1250 V
Average Anode Current 0.1 mA
Anode to Cathode Supply Voltage 1000 V
Luminous Sensitivity Min. 140 μA/lm
Luminous Sensitivity Typ. 250 μA/lm
Radiant Sensitivity Typ. 74 mA/W
Anode Luminous Sensitivity Min. 400 A/lm
Anode Luminous Sensitivity Typ. 2500 A/lm
Anode Radiant Sensitivity Typ. 7.4e5 A/W
Anode Dark Current (after 30min.) Typ. 3 nA
Anode Dark Current (after 30min.) Max. 50 nA
Time Response Rise Time Typ. 2.2 ns
Time Response Transit Time Typ. 22 ns
1,004.00 1004.0 USD
Price Valid only in North America

This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately - see below) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,030.00
In Stock
This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately - see below) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,030.00 1030.0 USD
Price Valid only in North America

This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,375.00
In Stock
This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,375.00 1375.0 USD
Price Valid only in North America

The cryogenic receiver modules offer the ultimate in sensitivity for any given wavelength range as well as maximum immunity to EMI, microphonics, and accidental mishandling. The standard EOS dewars, side-viewing or down-viewing, can be provided with built-in amplifiers for any of the photodiode or photoconductor components. Depending on the specific detector and sensitivity requirements, parts of the amplifier may be cooled along with the detector.

These cryogenic modules are unique in the industry in providing the ultimate in sensitivity, EMI immunity, and low microphonic noise. The standard units contain switchable gains, BNC outputs, and shielded power connections. Custom options include offset control, additional gain control, and multi-stage amplifiers.
2,985.00
In Stock
The cryogenic receiver modules offer the ultimate in sensitivity for any given wavelength range as well as maximum immunity to EMI, microphonics, and accidental mishandling. The standard EOS dewars, side-viewing or down-viewing, can be provided with built-in amplifiers for any of the photodiode or photoconductor components. Depending on the specific detector and sensitivity requirements, parts of the amplifier may be cooled along with the detector.

These cryogenic modules are unique in the industry in providing the ultimate in sensitivity, EMI immunity, and low microphonic noise. The standard units contain switchable gains, BNC outputs, and shielded power connections. Custom options include offset control, additional gain control, and multi-stage amplifiers.
2,985.00 2985.0 USD
Price Valid only in North America

Integral HV power supply and display unit
4 digits LCD display
Analog BNC output
Available AD data acquisition system for capture to computer
Cooling temperature: -20°C. Warm-up time 10 minutes
Note: Cooling temperature is dependent on ambient temperature
Includes a small water recirculator (required for operation)
6,697.00
Integral HV power supply and display unit
4 digits LCD display
Analog BNC output
Available AD data acquisition system for capture to computer
Cooling temperature: -20°C. Warm-up time 10 minutes
Note: Cooling temperature is dependent on ambient temperature
Includes a small water recirculator (required for operation)
6,697.00 6697.0 USD
Price Valid only in North America

4 digits LCD displays high voltage output signal
BNC analog signal ouput
External high voltage control for the PMT (for computer control)
Six time constants switchable from a front panel control (from .01ms to 1sec.)
Zero adjustment control to cancel the effect of dark current and stray light
Adjustable gain 1, 10, 100 and 1,000 X
Includes power supply.
2,398.00
In Stock
4 digits LCD displays high voltage output signal
BNC analog signal ouput
External high voltage control for the PMT (for computer control)
Six time constants switchable from a front panel control (from .01ms to 1sec.)
Zero adjustment control to cancel the effect of dark current and stray light
Adjustable gain 1, 10, 100 and 1,000 X
Includes power supply.
2,398.00 2398.0 USD
Price Valid only in North America

Sciencetech's LDA-2000 series of detectors are available in 256, 512, and 1024 linear pixel array elements. These detectors utilizes Hamamatsu's S390X and S838X series NMOS linear image sensor chips.These detectors are IR-sensitized silicon detectors with a spectral range between 200-1000 nm.

This unit includes the power supply and all cables and connections. Please note that software will need to be purchased separately. We recommend Sciencetech's own SciSpec software package.
6,877.00
In Stock
Sciencetech's LDA-2000 series of detectors are available in 256, 512, and 1024 linear pixel array elements. These detectors utilizes Hamamatsu's S390X and S838X series NMOS linear image sensor chips.These detectors are IR-sensitized silicon detectors with a spectral range between 200-1000 nm.

This unit includes the power supply and all cables and connections. Please note that software will need to be purchased separately. We recommend Sciencetech's own SciSpec software package.
6,877.00 6877.0 USD
Price Valid only in North America

An adjustable mount to attach CCDs to any of Sciencetech's line of monochromator/spectrometers. This mount will work specifically with Hamamatsu's line of CCDs: if you are uncertain if your CCD is a standard Hamamatsu CCD or not, please ask your Sciencetech representative.
1,365.00
In Stock
An adjustable mount to attach CCDs to any of Sciencetech's line of monochromator/spectrometers. This mount will work specifically with Hamamatsu's line of CCDs: if you are uncertain if your CCD is a standard Hamamatsu CCD or not, please ask your Sciencetech representative.
1,365.00 1365.0 USD
Price Valid only in North America
Copyright © Sciencetech