45 degree mirror to deflect the light 90 degrees, such that it points downwards for a horizontal target.
The cold mirror eliminates IR (thermal) light on the sample (Transmission > 85% for the region 800 - 1200nm, Reflection >90% for the region 425 - 650nm)


989.00
In Stock
45 degree mirror to deflect the light 90 degrees, such that it points downwards for a horizontal target.
The cold mirror eliminates IR (thermal) light on the sample (Transmission > 85% for the region 800 - 1200nm, Reflection >90% for the region 425 - 650nm)


989.00 989.0 USD

Price Valid only in North America


This high-powered filter passes visible light and blocks UV and NIR. This filter has an average transmission of 95% from 400-700 nm, and high reflection <400 nm and from 700-1200 nm. This filter is designed for 0 degree angle of incidence. This filter is mounted in a FT style filter holder and has a clear aperture of 73 mm diameter.
990.00
In Stock
This high-powered filter passes visible light and blocks UV and NIR. This filter has an average transmission of 95% from 400-700 nm, and high reflection <400 nm and from 700-1200 nm. This filter is designed for 0 degree angle of incidence. This filter is mounted in a FT style filter holder and has a clear aperture of 73 mm diameter.
990.00 990.0 USD

Price Valid only in North America


The SH-XLH-B is a computer controlled shutter for 201, LH-S, XLH-S lamp houses and SF/SLB solar simulators. Based on the successful SSES lines of blade shutters for Sciencetech's line of high powered solar simulators.
An arc lamp is not designed to be frequently turned off and on and doing so will dramatically lower its service life. In addition, each time it is turned on it requires the power supply to ignite it with a 20,000 V+ spark. The best option for performing exposure testing is to integrate an electronic shutter system with the lamp house or solar simulator. This electronic shutter has an activation time of <150 ms.

The SH-XLH-B can be controlled using Sciencetech PS-XE-series of computer-controlled touchscreen power supplies (e.g PS-XE300-A-T). This includes automated exposure time control. Manual models of the PS-XE (e.g. PS-XE300-A-M) cannot control this shutter. Alternatively, a shutter controller model SH-C and SCI-SHUTTER Software are available for controlling the shutter. The SH-C controller is not included with this shutter.

This shutter can be used with any high powered light source and can effectively block a 2" diameter beam.
This shutter is closed frame and the shutter mechanism is not exposed. For an open frame shutter please see the SH-2-B-OF product.
1,010.00
In Stock
The SH-XLH-B is a computer controlled shutter for 201, LH-S, XLH-S lamp houses and SF/SLB solar simulators. Based on the successful SSES lines of blade shutters for Sciencetech's line of high powered solar simulators.
An arc lamp is not designed to be frequently turned off and on and doing so will dramatically lower its service life. In addition, each time it is turned on it requires the power supply to ignite it with a 20,000 V+ spark. The best option for performing exposure testing is to integrate an electronic shutter system with the lamp house or solar simulator. This electronic shutter has an activation time of <150 ms.

The SH-XLH-B can be controlled using Sciencetech PS-XE-series of computer-controlled touchscreen power supplies (e.g PS-XE300-A-T). This includes automated exposure time control. Manual models of the PS-XE (e.g. PS-XE300-A-M) cannot control this shutter. Alternatively, a shutter controller model SH-C and SCI-SHUTTER Software are available for controlling the shutter. The SH-C controller is not included with this shutter.

This shutter can be used with any high powered light source and can effectively block a 2" diameter beam.
This shutter is closed frame and the shutter mechanism is not exposed. For an open frame shutter please see the SH-2-B-OF product.
1,010.00 1010.0 USD

Price Valid only in North America


A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 900nm.
Special feature: extra low dark current, transit time 22ns
input window: 6x8 mm

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
In Stock
A 28mm, side-on type PMT Tube from Hamamatsu.
The effective range is from 185nm to 900nm.
Special feature: extra low dark current, transit time 22ns
input window: 6x8 mm

For full technical specifications, please ask your authorized Sciencetech technical sales staff member.
1,030.00 1030.0 USD

Price Valid only in North America


Sciencetech's (SCP-2T) is an economical probe station that provides 2 tungsten needle-tip probes to provide contacts to the top surface of your test device.

Tungsten needle-tip probes are an excellent choice for applications requiring highly accurate, fine probe placement.
Please note: Tungsten needle-tip probes are very sharp and might not be suitable for some cell technologies. For such application, Gold spring loaded probes such as SCP-2G is recommended.
1,039.00
In Stock
Sciencetech's (SCP-2T) is an economical probe station that provides 2 tungsten needle-tip probes to provide contacts to the top surface of your test device.

Tungsten needle-tip probes are an excellent choice for applications requiring highly accurate, fine probe placement.
Please note: Tungsten needle-tip probes are very sharp and might not be suitable for some cell technologies. For such application, Gold spring loaded probes such as SCP-2G is recommended.
1,039.00 1039.0 USD

Price Valid only in North America


This is a high resolution slit designed to have 10 um resolution. The slits are manufactured from stainless steel to maximize mechanical accuracy. The height of the SS-84 slit can also be adjusted between 0-10 mm, 10-20 mm and 20-30 mm through built-in manual curtain sliders.

Please note that these slits are not designed to maximize throughput for extremely high resolution monochromators, due to the straight orientation of the slits. For maximum resolution, the slits need to be designed on a curve that corresponds to the curvature of the point of least confusion. However, this is only a significant factor for systems with optical pathlengths of 1m and greater. Please speak with your authorized Sciencetech technical sales staff member if you need maximum resolution for a long pathlength system.
1,040.00
In Stock
This is a high resolution slit designed to have 10 um resolution. The slits are manufactured from stainless steel to maximize mechanical accuracy. The height of the SS-84 slit can also be adjusted between 0-10 mm, 10-20 mm and 20-30 mm through built-in manual curtain sliders.

Please note that these slits are not designed to maximize throughput for extremely high resolution monochromators, due to the straight orientation of the slits. For maximum resolution, the slits need to be designed on a curve that corresponds to the curvature of the point of least confusion. However, this is only a significant factor for systems with optical pathlengths of 1m and greater. Please speak with your authorized Sciencetech technical sales staff member if you need maximum resolution for a long pathlength system.
1,040.00 1040.0 USD

Price Valid only in North America


An F/2 off-axis parabolic mirror assembly with protected aluminum mirror coating. This assembly is intended to attach to Sciencetech's LH-S lamp houses (also works with obsolete 201C-100 lamp houses). The assembly includes a kinematic three point adjuster to optimize optical alignment. A standard hole pattern on the input and output ends of the assembly can be used to mount this optical component to custom or third party systems with appropriate bracketing.
1,061.00
In Stock
An F/2 off-axis parabolic mirror assembly with protected aluminum mirror coating. This assembly is intended to attach to Sciencetech's LH-S lamp houses (also works with obsolete 201C-100 lamp houses). The assembly includes a kinematic three point adjuster to optimize optical alignment. A standard hole pattern on the input and output ends of the assembly can be used to mount this optical component to custom or third party systems with appropriate bracketing.
1,061.00 1061.0 USD

Price Valid only in North America


Sciencetech's Compact 1.75" Optical Liquid Filter is designed to filter wavelengths 1000nm and greater (if distilled water is used). The compact size allows it to be installed in one of Sciencetech's FHV- style filter boxes. The FHV filter box is required to interface this filter with a Sciencetech optical system. This filter requires a cooling water recirculator (sold separately).
1,110.00
In Stock
Sciencetech's Compact 1.75" Optical Liquid Filter is designed to filter wavelengths 1000nm and greater (if distilled water is used). The compact size allows it to be installed in one of Sciencetech's FHV- style filter boxes. The FHV filter box is required to interface this filter with a Sciencetech optical system. This filter requires a cooling water recirculator (sold separately).
1,110.00 1110.0 USD

Price Valid only in North America


This data acquisition module features 3 analog inputs via BNC connectors. The data acquisition board is 12-bit and can measure a single channel up to 50 kS/s. An additional BNC connector for a multi-purpose digital input/output can be used to time measurements and/or send signals to external hardware such as a high speed shutter.

This module includes 1 BNC cable and 1 USB cable so that it is ready to interface with a single channel detector such as a PMT or Si photodiode detector (sold separately). For spectroscopy systems the SciSpec Windows application software to interface with a Windows Based PC is required and is sold separately.

Multi-channel data acquisition is possible using SciSpec software, if this option is required please speak to a Sciencetech technical sales representative.
1,110.00
In Stock
This data acquisition module features 3 analog inputs via BNC connectors. The data acquisition board is 12-bit and can measure a single channel up to 50 kS/s. An additional BNC connector for a multi-purpose digital input/output can be used to time measurements and/or send signals to external hardware such as a high speed shutter.

This module includes 1 BNC cable and 1 USB cable so that it is ready to interface with a single channel detector such as a PMT or Si photodiode detector (sold separately). For spectroscopy systems the SciSpec Windows application software to interface with a Windows Based PC is required and is sold separately.

Multi-channel data acquisition is possible using SciSpec software, if this option is required please speak to a Sciencetech technical sales representative.
1,110.00 1110.0 USD

Price Valid only in North America


Sciencetech's (SCP-SP-T) is a micropositioning probe station with a magnetic base and a tungsten needle-tip probe. It utilizes thumbscrews for adjustment. 0.3” is the magnitude of fine adjustment for this probe.

Tungsten needle-tip probes are an excellent choice for applications requiring highly accurate, fine probe placement.
1,150.00
In Stock
Sciencetech's (SCP-SP-T) is a micropositioning probe station with a magnetic base and a tungsten needle-tip probe. It utilizes thumbscrews for adjustment. 0.3” is the magnitude of fine adjustment for this probe.

Tungsten needle-tip probes are an excellent choice for applications requiring highly accurate, fine probe placement.
1,150.00 1150.0 USD

Price Valid only in North America


An arc lamp is not designed to be frequently turned off and on and doing so will dramatically lower its service life. In addition, each time it is turned on it requires the power supply to ignite it with a 20,000V+ spark. THe best option for performing exposure testing is to integrate an electronic shutter system inside the beam homogenizer. The electronic shutter is computer controlled with an activation time of <150ms. Software for the shutter controller is included with this item. The standard shutter controller connects to a computer via RS232. RS232-USB converters are available and work with this product. In addition to computer control the shutter can be controlled via a toggle switch on the shutter controller box.

This shutter can be used with any high powered light source and can effectivley block a 5" diameter beam. See the brochure information for a mounting pattern.

This device can be controllable through Sciencetech's new line of Touch Screen power supplies (including automated explosure time control).
Please note leaving the shutter closed for exteremly long periods of time while the arc lamp is on may cause damage to the motorized components.
An arc lamp is not designed to be frequently turned off and on and doing so will dramatically lower its service life. In addition, each time it is turned on it requires the power supply to ignite it with a 20,000V+ spark. THe best option for performing exposure testing is to integrate an electronic shutter system inside the beam homogenizer. The electronic shutter is computer controlled with an activation time of <150ms. Software for the shutter controller is included with this item. The standard shutter controller connects to a computer via RS232. RS232-USB converters are available and work with this product. In addition to computer control the shutter can be controlled via a toggle switch on the shutter controller box.

This shutter can be used with any high powered light source and can effectivley block a 5" diameter beam. See the brochure information for a mounting pattern.

This device can be controllable through Sciencetech's new line of Touch Screen power supplies (including automated explosure time control).
Please note leaving the shutter closed for exteremly long periods of time while the arc lamp is on may cause damage to the motorized components.
1,308.00 1308.0 USD

Price Valid only in North America


Sciencetech’s (SCP-SP-G) is a micropositioning probe station with a magnetic base and a gold-plated spring probe. It utilizes thumbscrews for adjustment. 0.3” is the magnitude of fine adjustment for this probe.

Gold spring probes are an excellent choice for most applications, with the probe tip gently contacting the surface of your test device. For applications requiring finer probe placement, please see our tungsten needle-tip probe stations.
1,312.00
In Stock
Sciencetech’s (SCP-SP-G) is a micropositioning probe station with a magnetic base and a gold-plated spring probe. It utilizes thumbscrews for adjustment. 0.3” is the magnitude of fine adjustment for this probe.

Gold spring probes are an excellent choice for most applications, with the probe tip gently contacting the surface of your test device. For applications requiring finer probe placement, please see our tungsten needle-tip probe stations.
1,312.00 1312.0 USD

Price Valid only in North America


Multialkali high sensitivity side-on PMT
Spectral range: 185-900 nm,
Peak sensitivity wavelength: 400nm
Glass UV Envelope

Photocathode Area Size 8 x 24 mm
Photocathode Material Multialkali
Window Material UV glass
Dynode Structure Circular-cage
Anode to Cathode Voltage 1250 V
Average Anode Current 0.1 mA
Anode to Cathode Supply Voltage 1000 V
Luminous Sensitivity Min. 140 μA/lm
Luminous Sensitivity Typ. 250 μA/lm
Radiant Sensitivity Typ. 74 mA/W
Anode Luminous Sensitivity Min. 400 A/lm
Anode Luminous Sensitivity Typ. 2500 A/lm
Anode Radiant Sensitivity Typ. 7.4e5 A/W
Anode Dark Current (after 30min.) Typ. 3 nA
Anode Dark Current (after 30min.) Max. 50 nA
Time Response Rise Time Typ. 2.2 ns
Time Response Transit Time Typ. 22 ns
Multialkali high sensitivity side-on PMT
Spectral range: 185-900 nm,
Peak sensitivity wavelength: 400nm
Glass UV Envelope

Photocathode Area Size 8 x 24 mm
Photocathode Material Multialkali
Window Material UV glass
Dynode Structure Circular-cage
Anode to Cathode Voltage 1250 V
Average Anode Current 0.1 mA
Anode to Cathode Supply Voltage 1000 V
Luminous Sensitivity Min. 140 μA/lm
Luminous Sensitivity Typ. 250 μA/lm
Radiant Sensitivity Typ. 74 mA/W
Anode Luminous Sensitivity Min. 400 A/lm
Anode Luminous Sensitivity Typ. 2500 A/lm
Anode Radiant Sensitivity Typ. 7.4e5 A/W
Anode Dark Current (after 30min.) Typ. 3 nA
Anode Dark Current (after 30min.) Max. 50 nA
Time Response Rise Time Typ. 2.2 ns
Time Response Transit Time Typ. 22 ns
1,312.00 1312.0 USD

Price Valid only in North America


A 300W xenon short arc lamp bulb, using a fused silica glass envelope. Please note that this lamp produces ozone.
1,364.00
In Stock
A 300W xenon short arc lamp bulb, using a fused silica glass envelope. Please note that this lamp produces ozone.
1,364.00 1364.0 USD

Price Valid only in North America


The CTBT-RF is designed to work with Sciencetech's line of SS solar simulators (between 500W and 1.6kW). The CTBT-RF is designed to hold 3" x 4" cold mirrors. A heat sink is mounted behind the dichroic turning mirror to capture transmitted light. The CTBT-RF turns the beam 90 degrees from the standard horizontal output.


Four different cold mirror options exist (purchased separately):
1) 275-375nm
2) 325-450nm
3) 350-550nm
4) 450-725nm
5) UV Enhanced aluminum mirror (250-3000nm)


Please speak with your Sciencetech representative for ordering information.
1,364.00
In Stock
The CTBT-RF is designed to work with Sciencetech's line of SS solar simulators (between 500W and 1.6kW). The CTBT-RF is designed to hold 3" x 4" cold mirrors. A heat sink is mounted behind the dichroic turning mirror to capture transmitted light. The CTBT-RF turns the beam 90 degrees from the standard horizontal output.


Four different cold mirror options exist (purchased separately):
1) 275-375nm
2) 325-450nm
3) 350-550nm
4) 450-725nm
5) UV Enhanced aluminum mirror (250-3000nm)


Please speak with your Sciencetech representative for ordering information.
1,364.00 1364.0 USD

Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concentrator solar simulators (5 Suns +, 500 mW/cm2).
In Stock
This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concentrator solar simulators (5 Suns +, 500 mW/cm2).
1,389.00 1389.0 USD

Price Valid only in North America


An AM0 filter compatible with Sciencetech solar simulators, including FT-style filter holder. Filter clear aperture is a diameter of 76 mm (3"). Please select the product line the filter is intended to be used with to ensure the proper spectral output.

AM0 simulates the solar spectrum just outside Earth’s atmosphere, where there is very little atmosphere-related absorption of solar radiation. This is generally used for space applications.
1,394.00
An AM0 filter compatible with Sciencetech solar simulators, including FT-style filter holder. Filter clear aperture is a diameter of 76 mm (3"). Please select the product line the filter is intended to be used with to ensure the proper spectral output.

AM0 simulates the solar spectrum just outside Earth’s atmosphere, where there is very little atmosphere-related absorption of solar radiation. This is generally used for space applications.
1,394.00 1394.0 USD

Price Valid only in North America


An AM1.5D filter compatible with Sciencetech solar simulators, including FT-style filter holder. Filter clear aperture is a diameter of 76 mm (3"). Please select the product line the filter is intended to be used with to ensure the proper spectral output.

AM1.5D simulates the terrestrial solar spectrum on the ground when the sun is at a zenith angle of 48.2°. It includes only direct light from the sun, and not the diffuse light that is scattered by the atmosphere. As a result, this filter simulates the direct radiation which reaches the ground.

Please note that for some simulator models the same filter is used to supply an AM1.5G spectral match. Purchasing separate AM1.5G and AM1.5D filters for the same model simulator may not provide a different spectrum.
1,394.00
An AM1.5D filter compatible with Sciencetech solar simulators, including FT-style filter holder. Filter clear aperture is a diameter of 76 mm (3"). Please select the product line the filter is intended to be used with to ensure the proper spectral output.

AM1.5D simulates the terrestrial solar spectrum on the ground when the sun is at a zenith angle of 48.2°. It includes only direct light from the sun, and not the diffuse light that is scattered by the atmosphere. As a result, this filter simulates the direct radiation which reaches the ground.

Please note that for some simulator models the same filter is used to supply an AM1.5G spectral match. Purchasing separate AM1.5G and AM1.5D filters for the same model simulator may not provide a different spectrum.
1,394.00 1394.0 USD

Price Valid only in North America


An AM1.5G filter compatible with Sciencetech solar simulators, including FT-style filter holder. Filter clear aperture is a diameter of 76 mm (3"). Please select the product line the filter is intended to be used with to ensure the proper spectral output.

If the filter is not intended to be used with a Sciencetech solar simulator, the product line "None" may be selected, but the spectral output cannot be guaranteed when paired with a non-Sciencetech source.

AM1.5G simulates the terrestrial solar spectrum on the ground when the sun is at a zenith angle of 48.2°. It includes both direct light from the sun, and the diffuse light that is scattered by the atmosphere. As a result, this filter simulates the total radiation, known as global radiation, which reaches the ground.
1,394.00
An AM1.5G filter compatible with Sciencetech solar simulators, including FT-style filter holder. Filter clear aperture is a diameter of 76 mm (3"). Please select the product line the filter is intended to be used with to ensure the proper spectral output.

If the filter is not intended to be used with a Sciencetech solar simulator, the product line "None" may be selected, but the spectral output cannot be guaranteed when paired with a non-Sciencetech source.

AM1.5G simulates the terrestrial solar spectrum on the ground when the sun is at a zenith angle of 48.2°. It includes both direct light from the sun, and the diffuse light that is scattered by the atmosphere. As a result, this filter simulates the total radiation, known as global radiation, which reaches the ground.
1,394.00 1394.0 USD

Price Valid only in North America


This data acquisition module features 3 analog inputs via BNC connectors. The data acquisition board is 16-bit and can measure a single channel up to 50 kS/s. An additional BNC connector for a multi-purpose digital input/output can be used to time measurements and/or send signals to external hardware such as a high speed shutter.

This module includes 1 BNC cable and 1 USB cable so that it is ready to interface with a single channel detector such as a PMT or Si photodiode detector (sold separately). For spectroscopy systems the SciSpec Windows application software to interface with a Windows Based PC is required and is sold separately.

Multi-channel data acquisition is possible using SciSpec software, if this option is required please speak to a Sciencetech technical sales representative.
1,413.00
In Stock
This data acquisition module features 3 analog inputs via BNC connectors. The data acquisition board is 16-bit and can measure a single channel up to 50 kS/s. An additional BNC connector for a multi-purpose digital input/output can be used to time measurements and/or send signals to external hardware such as a high speed shutter.

This module includes 1 BNC cable and 1 USB cable so that it is ready to interface with a single channel detector such as a PMT or Si photodiode detector (sold separately). For spectroscopy systems the SciSpec Windows application software to interface with a Windows Based PC is required and is sold separately.

Multi-channel data acquisition is possible using SciSpec software, if this option is required please speak to a Sciencetech technical sales representative.
1,413.00 1413.0 USD