Accessories and Parts | Sciencetech Inc.

Accessories / Parts

X

Product Category

View Filter

x
Clear all x

Filter Option



An AM1.5G filter compatible with Sciencetech solar simulators, including FT-style filter holder. Filter clear aperture is a diameter of 76 mm (3"). Please select the product line the filter is intended to be used with to ensure the proper spectral output.

If the filter is not intended to be used with a Sciencetech solar simulator, the product line "None" may be selected, but the spectral output cannot be guaranteed when paired with a non-Sciencetech source.

AM1.5G simulates the terrestrial solar spectrum on the ground when the sun is at a zenith angle of 48.2°. It includes both direct light from the sun, and the diffuse light that is scattered by the atmosphere. As a result, this filter simulates the total radiation, known as global radiation, which reaches the ground.
1,380.00
An AM1.5G filter compatible with Sciencetech solar simulators, including FT-style filter holder. Filter clear aperture is a diameter of 76 mm (3"). Please select the product line the filter is intended to be used with to ensure the proper spectral output.

If the filter is not intended to be used with a Sciencetech solar simulator, the product line "None" may be selected, but the spectral output cannot be guaranteed when paired with a non-Sciencetech source.

AM1.5G simulates the terrestrial solar spectrum on the ground when the sun is at a zenith angle of 48.2°. It includes both direct light from the sun, and the diffuse light that is scattered by the atmosphere. As a result, this filter simulates the total radiation, known as global radiation, which reaches the ground.
1,380.00 1380.0 USD
Price Valid only in North America


Material: Si
Wavelength Range: 350-1100
Detector Size: 3.6 x 3.6mm
Gain (Fixed): 8 x 10 dB steps
Bandwidth Range: DC - 17MHz
NEP: 2.1x10^(-12) to 7.7x10^(-11) W/Hz^(1/2)
650.00
In stock
Material: Si
Wavelength Range: 350-1100
Detector Size: 3.6 x 3.6mm
Gain (Fixed): 8 x 10 dB steps
Bandwidth Range: DC - 17MHz
NEP: 2.1x10^(-12) to 7.7x10^(-11) W/Hz^(1/2)
650.00 650.0 USD
Price Valid only in North America


Material: Si
Wavelength Range: 350-1100
Detector Size: 0.8mm diameter
Gain (Fixed): 100kV/A
Bandwidth Range: DC - 50MHz
NEP: 6.5x10^(-11) W/Hz^(1/2)
800.00
In stock
Material: Si
Wavelength Range: 350-1100
Detector Size: 0.8mm diameter
Gain (Fixed): 100kV/A
Bandwidth Range: DC - 50MHz
NEP: 6.5x10^(-11) W/Hz^(1/2)
800.00 800.0 USD
Price Valid only in North America


Material: Si
Wavelength Range: 200-1100
Detector Size: 1.0mm diameter
Gain (Fixed): 10kV/A
Bandwidth Range: DC - 150MHz
NEP: 5.5x10^(-11) W/Hz^(1/2)
632.00
In stock
Material: Si
Wavelength Range: 200-1100
Detector Size: 1.0mm diameter
Gain (Fixed): 10kV/A
Bandwidth Range: DC - 150MHz
NEP: 5.5x10^(-11) W/Hz^(1/2)
632.00 632.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00
In stock
This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W (0.5 uW NEP). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

This thermopile is recommended for smaller light sources (collimated 500W arc lamps and below) and standard solar simulators (<5 Suns, <500 mW/cm2).
1,727.00 1727.0 USD
Price Valid only in North America


4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00
In stock
4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software.

Sensitivity 0.4 mW/W,
rise time 7 sec,
spectral range 0.19-20um.
7,911.00 7911.0 USD
Price Valid only in North America


This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,375.00
In stock
This Broadband Thermopile Detector allows the measurement of total broadband radiation emitted by a light source. It could also be used to measure the light power density on a surface (in W/cm2) which is particularly useful for uniformity measurements and for checking solar simulator performance. This detector has a 19mm diameter sensor and picks up all wavelengths between 190-11μm (UV-VIS-IR). Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only. (1mW NEP).

This thermopile is recommended for high-powered light sources (such as focused 500W + arc lamps) and concetrator solar simulators (5 Suns +, 500 mW/cm2).
1,375.00 1375.0 USD
Price Valid only in North America


This broadband IR area detector has a sensor size of 320 x 240 pixels and a spectral range of 2-14 μm. The pixel size is 48.5μm square. The sensor is an uncooled pyroelectric BST (Barium, Strontium, Titanate) array. Because of the nature of pyroelectric sensors, there is an internal Archimedes spiral chopper that recalibrates the image. However, this calibration system, called an Auto Image Calibration, is actually a benefit for the user. The detector self calibrates to a reference 60 times per second, which in turn causes the system to be extremely stable and to have very little fixed pattern noise.
21,121.00
This broadband IR area detector has a sensor size of 320 x 240 pixels and a spectral range of 2-14 μm. The pixel size is 48.5μm square. The sensor is an uncooled pyroelectric BST (Barium, Strontium, Titanate) array. Because of the nature of pyroelectric sensors, there is an internal Archimedes spiral chopper that recalibrates the image. However, this calibration system, called an Auto Image Calibration, is actually a benefit for the user. The detector self calibrates to a reference 60 times per second, which in turn causes the system to be extremely stable and to have very little fixed pattern noise.
21,121.00 21121.0 USD
Price Valid only in North America


1,000.00 1000.0 USD
Price Valid only in North America


Alphalas 3648 pixel linear CCD.
UV to IR spectral range 200 - 1100 nm, 16-bit ADC, large 32 MB of fast DDR2 onboard RAM, max. 269.5 fps, high-speed USB 2.0
Housing: 90 x 25 x 105 mm (W x H x D)
Comes with specific USB power/signal cable for interfacing to a computer.
Works with Sciencetech SciSpec Software integrating camera readout and monochromator position information. This camera is also compatible with LabView. A C++ programming library is available for this camera at extra cost.

This camera can also be triggered using TTL signals making it a perfect option for interfacing with Sciencetech's high speed shutters for decay measurements.
2,717.00
In stock
Alphalas 3648 pixel linear CCD.
UV to IR spectral range 200 - 1100 nm, 16-bit ADC, large 32 MB of fast DDR2 onboard RAM, max. 269.5 fps, high-speed USB 2.0
Housing: 90 x 25 x 105 mm (W x H x D)
Comes with specific USB power/signal cable for interfacing to a computer.
Works with Sciencetech SciSpec Software integrating camera readout and monochromator position information. This camera is also compatible with LabView. A C++ programming library is available for this camera at extra cost.

This camera can also be triggered using TTL signals making it a perfect option for interfacing with Sciencetech's high speed shutters for decay measurements.
2,717.00 2717.0 USD
Price Valid only in North America


Rotating blade chopper
2 opening blade for frequency range of 4-200Hz.
Higher frequency ranges available with other blades.
Includes enclosure and driver
1-D slip ring with H4 hole pattern on input face, 2-D slip ring with S4 hole pattern on output face for integration with Sciencetech modular instruments.
** Warning ** This chopper accepts a maximum 1" diameter collimated beam at the chopper port. For 1" diameter collimated beams the CH-MC-E-1D1D chopper is usually used.
The CH-MC-E-1D2D chopper is usually used in cases where a convergent beam enters the chopper housing from a 2" optical tube.


This chopper is compatible with SciSpec and SciPV software. For integration into Sciencetech instruments or larger integrated systems see SciencetechCOM and SciAX software.

Third party control software is included with this chopper but is not supported by Sciencetech.
2,472.00
In stock
Rotating blade chopper
2 opening blade for frequency range of 4-200Hz.
Higher frequency ranges available with other blades.
Includes enclosure and driver
1-D slip ring with H4 hole pattern on input face, 2-D slip ring with S4 hole pattern on output face for integration with Sciencetech modular instruments.
** Warning ** This chopper accepts a maximum 1" diameter collimated beam at the chopper port. For 1" diameter collimated beams the CH-MC-E-1D1D chopper is usually used.
The CH-MC-E-1D2D chopper is usually used in cases where a convergent beam enters the chopper housing from a 2" optical tube.


This chopper is compatible with SciSpec and SciPV software. For integration into Sciencetech instruments or larger integrated systems see SciencetechCOM and SciAX software.

Third party control software is included with this chopper but is not supported by Sciencetech.
2,472.00 2472.0 USD
Price Valid only in North America


The C230X Chopper is a Sciencetech manufactured chopper for high precision applications requiring a vacuum-grade polarizing chopper and better accuracy than is available through most commercially available chopper systems.
This product is the enclosure required to mount one of these choppers to any system. Please discuss the exact desired location of the chopper relative to the rest of your system with your authorized Sciencetech technical sales staff member to ensure that your system meets all technical specifications and requirements.
650.00
In stock
The C230X Chopper is a Sciencetech manufactured chopper for high precision applications requiring a vacuum-grade polarizing chopper and better accuracy than is available through most commercially available chopper systems.
This product is the enclosure required to mount one of these choppers to any system. Please discuss the exact desired location of the chopper relative to the rest of your system with your authorized Sciencetech technical sales staff member to ensure that your system meets all technical specifications and requirements.
650.00 650.0 USD
Price Valid only in North America


Many systems require choppers for modulating signals (either inputs or outputs, depending on the system and detector, and the specific needs for modulation for the system). A chopper is normally the most effective way to do this.
However, the chopper normally requires a housing to hold the chopper in the proper position in the system. This particular housing is designed to allow a chopper to be mounted to either the input or output port of a Sciencetech monochromator or spectrograph.
If you have any questions about how this mounting may affect your system, please speak with your authorized Sciencetech technical sales staff member.
600.00
In stock
Many systems require choppers for modulating signals (either inputs or outputs, depending on the system and detector, and the specific needs for modulation for the system). A chopper is normally the most effective way to do this.
However, the chopper normally requires a housing to hold the chopper in the proper position in the system. This particular housing is designed to allow a chopper to be mounted to either the input or output port of a Sciencetech monochromator or spectrograph.
If you have any questions about how this mounting may affect your system, please speak with your authorized Sciencetech technical sales staff member.
600.00 600.0 USD
Price Valid only in North America


Sciencetech's sample chambers can be connected to either the input or output port of a Sciencetech monochromator/spectrograph. The coupling tube that connects them together is 1" in diameter, and has one lens with a matching monochromator F number. When the sample chamber is connected to the input port of a monochromator/spectrograph, collimated light from the sample chamber is then focused into the slit of the monochromator matching its input F number using a single lens. When the sample chamber is connected to the output port of a monochromator, the output light of the monochromator is collected by a single lens with matching output F number and then collimated for entry into the sample chamber.
This product includes the F-matching lens, tubes, and mechanical connections required to couple the sample chamber to the monochromator. Please specify if this will be an input or output coupling when ordering. This product will only work for Sciencetech's line of sample chambers: for custom optical coupling, please speak with your authorized Sciencetech technical sales staff member.
909.00
In stock
Sciencetech's sample chambers can be connected to either the input or output port of a Sciencetech monochromator/spectrograph. The coupling tube that connects them together is 1" in diameter, and has one lens with a matching monochromator F number. When the sample chamber is connected to the input port of a monochromator/spectrograph, collimated light from the sample chamber is then focused into the slit of the monochromator matching its input F number using a single lens. When the sample chamber is connected to the output port of a monochromator, the output light of the monochromator is collected by a single lens with matching output F number and then collimated for entry into the sample chamber.
This product includes the F-matching lens, tubes, and mechanical connections required to couple the sample chamber to the monochromator. Please specify if this will be an input or output coupling when ordering. This product will only work for Sciencetech's line of sample chambers: for custom optical coupling, please speak with your authorized Sciencetech technical sales staff member.
909.00 909.0 USD
Price Valid only in North America


Sciencetech's sample chambers can be connected to either the input or output port of a Sciencetech monochromator/spectrograph. The coupling tube that connects them together is 1" in diameter, and has one lens with a matching monochromator F number. When the sample chamber is connected to the input port of a monochromator/spectrograph, collimated light from the sample chamber is then focused into the slit of the monochromator matching its input F number using a single lens. When the sample chamber is connected to the output port of a monochromator, the output light of the monochromator is collected by a single lens with matching output F number and then collimated for entry into the sample chamber.
This product includes the F-matching lens, tubes, and mechanical connections required to couple the sample chamber to the monochromator. Please specify if this will be an input or output coupling when ordering. This product will only work for Sciencetech's line of sample chambers: for custom optical coupling, please speak with your authorized Sciencetech technical sales staff member.
909.00
In stock
Sciencetech's sample chambers can be connected to either the input or output port of a Sciencetech monochromator/spectrograph. The coupling tube that connects them together is 1" in diameter, and has one lens with a matching monochromator F number. When the sample chamber is connected to the input port of a monochromator/spectrograph, collimated light from the sample chamber is then focused into the slit of the monochromator matching its input F number using a single lens. When the sample chamber is connected to the output port of a monochromator, the output light of the monochromator is collected by a single lens with matching output F number and then collimated for entry into the sample chamber.
This product includes the F-matching lens, tubes, and mechanical connections required to couple the sample chamber to the monochromator. Please specify if this will be an input or output coupling when ordering. This product will only work for Sciencetech's line of sample chambers: for custom optical coupling, please speak with your authorized Sciencetech technical sales staff member.
909.00 909.0 USD
Price Valid only in North America


This adapter couples light from a standard FC terminated fiber (0.22NA) to an F/3 monochromator input port. The fiber can be adjusted +- 6mm in X and Y directions to optimize the alignment. The optical lenses are made from fused silica giving good transmission over a wavelength range of 200nm-2000nm
1,210.00
In stock
This adapter couples light from a standard FC terminated fiber (0.22NA) to an F/3 monochromator input port. The fiber can be adjusted +- 6mm in X and Y directions to optimize the alignment. The optical lenses are made from fused silica giving good transmission over a wavelength range of 200nm-2000nm
1,210.00 1210.0 USD
Price Valid only in North America


This assembly is a customizable F/# matched, 1" diameter, double lens assembly.
The Lens material selected will be Fused Quartz or Fused Silica depending on availability. Best used in the spectral range 250-2500nm

The CON1 lens assemblies are designed to accept collimated light and produce a focused beam at the intended target location
Please specify the required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
The required F/# must be entered in the sales order notes for efficient processing

Accessories and adapters for coupling available.
585.00
In stock
This assembly is a customizable F/# matched, 1" diameter, double lens assembly.
The Lens material selected will be Fused Quartz or Fused Silica depending on availability. Best used in the spectral range 250-2500nm

The CON1 lens assemblies are designed to accept collimated light and produce a focused beam at the intended target location
Please specify the required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
The required F/# must be entered in the sales order notes for efficient processing

Accessories and adapters for coupling available.
585.00 585.0 USD
Price Valid only in North America


This assembly is a custom F/# matched lens assembly. It is a double lens assembly of 1" diameter PCX lenses.
Lens material is BK7 Glass.
Specify required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
Lenses mounted in 1" diameter coupling tube. Accessories and adapters for coupling available.
459.00
In stock
This assembly is a custom F/# matched lens assembly. It is a double lens assembly of 1" diameter PCX lenses.
Lens material is BK7 Glass.
Specify required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
Lenses mounted in 1" diameter coupling tube. Accessories and adapters for coupling available.
459.00 459.0 USD
Price Valid only in North America


This optical coupler can be used to couple beam line components and allows for independent adjustment of +-3mm along each of two orthogonal axis. This coupler is intended to mate one end to either a 1-D or 4S connection. The other end accepts any component with a 1.035-40 thread. With the CON1-XY-T1 the optical alignment of optical elements such as optical fibers can be optimized to monochromator input slits or target locations.

200.00
In stock
This optical coupler can be used to couple beam line components and allows for independent adjustment of +-3mm along each of two orthogonal axis. This coupler is intended to mate one end to either a 1-D or 4S connection. The other end accepts any component with a 1.035-40 thread. With the CON1-XY-T1 the optical alignment of optical elements such as optical fibers can be optimized to monochromator input slits or target locations.

200.00 200.0 USD
Price Valid only in North America


This assembly is a custom F/# matched lens assembly. It is a single lens assembly of 2" diameter PCX lenses.
Lens material is Fused Quartz or Fused Silica depending on availability.
Specify required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
Lenses mounted in 2.2" diameter coupling tube. Accessories and adapters for coupling available.
442.00
In stock
This assembly is a custom F/# matched lens assembly. It is a single lens assembly of 2" diameter PCX lenses.
Lens material is Fused Quartz or Fused Silica depending on availability.
Specify required F/# at time of ordering. F/# can be set from F/0.8 to F/10.0
Lenses mounted in 2.2" diameter coupling tube. Accessories and adapters for coupling available.
442.00 442.0 USD
Price Valid only in North America
Copyright © Sciencetech