12-bit Data Acquisition AD Board - Standard

Main Features: 
  • 12-bit A/D resolution
  • 16 channels (only one used)
  • 250kHz sampling rate(standard model)
  • 150kHz sampling rate(high gain model)
  • 24 digital IO (only one used for optional shutter)
  • Three 16-bit counters (high gain model only, though not used)
  • Dual 12-bit D/As (high gain model only, though not used)
  • Gains of 1,2,4,8 (standard model)
  • Gains of 1, 10, 100, 1000 (high gain model)
  • Windows 98 and XP drivers
  • Compatible with Sciencetech SCI-LDA, SCI-SPEC, READ-LDA Active-X and
    READ-DETECTOR Active-X software

This 12-bit AD board is recommended for the following detectors:

  • Non-cooled PMT detectors
  • PDA linear array detectors
  • Non-cooled single channel detectors

This 12-bit AD board is not recommended for the following, where 16-bit boards should be used.

  • Cooled PMT
  • CCD detectors
12-bit Data Acquisition AD Board
SKU: PCI-AD1000-std

A PCI data acquisition board is required to digitize the detector signal into the computer and control its shutter (if available). Sciencetech’s 12-bit Data Acquisition System consist of a BNC to ribbon cable connector for data connection to the detector, a 12-bit A/D PCI data acquisition board, and Sciencetech’s Windows based SCI-SPEC or Sci-LDA software application to display and save digitized detector data in real-time. The detector head is connected to the BNC to Ribbon cable which is then connected to the 12-bit A/D PCI data acquisition board inside a Windows based computer’s available PCI slot. A 16-bit A/D is also available for cooled detectors in sensitive low noise applications. This board can also control the Uniblize shutter using Sciencetech's Read-LDA Active-X software and a separate BNC connector (included).

Operating Systems
This PCI AD board works in Win 98/2000/XP. Sciencetech's Sci-Spec, Sci-LDA, Read-LDA Active-X, and Read-Detector Active-X software work with this AD board through these operating systems.

Shutter Control Version
This PCI AD Board is also capable of controlling an internal shutter. Sciencetech's Sci-LDA software already has this shutter feature built in, and so does the Sciencetech Read-LDA Active-X software. If Sci-LDA software is required, it must be purchased separately. Sciencetech Read-LDA Active X software and cable are included with the AD Data acquisition option.

BNC Connector Interface
Please note that the AD Board on its own does not have a BNC connector for interfacing to the analog detector or optional shutter. A BNC cable (different for detector or shutter) must be purchased separately.

Technical Specifications

Standard Model
Speed: 250KHz
Resolution: 12-bit
GAIN Settings: ±10V, ±5V, ±2.5V, ±1.25V.

High Gain Model
Speed: 150KHz
Resolution: 12-bit
GAIN Setting: ±10V, ±1V, ±0.1V, ±0.01V, 0 to 10V, 0 to 1V, 0 to 0.1V, 0 to 0.01V

Price: $733.00